SAFETY INFORMATION

The stopping system of the machine must be electrically controlled.

This control system must be able to stop the dangerous movement of the machine within the total 
machine stopping time T as per paragraph “Minimum installation distance” of the Instruction Man-
ual and during all working cycle phases.

Mounting and connection of the safety light curtain must be carried out by qualified personnel only, 
according to the indications included in the Instruction Manual (refer to paragraphs “Installation”, 
“Mechanical Mounting”, “Electrical Connections”, “Alignment Procedure”) and in the applicable 
standards.

The safety light curtain must be securely placed in a particular position so that access to the danger-
ous zone is not possible without the interruption of the beams (refer to paragraph “Installation” in 
the Instruction Manual).

The personnel operating in the dangerous area must be well trained and must have adequate knowl-
edge of all the operating procedures of the safety light curtain.

The Restart button must be located outside the dangerous zone because the operator must check 
the dangerous zone during all Restart operations.

NOTE

Precautions to be observed for the choice and installation

Use only matched emitter and receiver pairs with same serial no.

The outputs (OSSD) of the ESPE must be used as machine stopping devices and not as command 
devices.

The machine must have its own START command.

The dimension of the smallest object to be detected must be larger than the resolution level of the 
device.

The ESPE must be installed in an environment complying with the characteristics indicated in chapter 
“Technical data” of the Instruction Manual.

The ESPE must not be installed close to strong and/or flashing light sources, in particular close to the 
front window of receiving unit.

The presence of intense electromagnetic disturbances could affect device’s correct operation.

This condition shall be carefully assessed with the advice of DATALOGIC Technical Service.

The operating distance of the device can be reduced in presence of smog, fog or airborne dust.

A sudden change in environment temperature, with very low minimum peaks, can generate a small 
condensation layer on the lenses and thus jeopardize correct operation.

CAUTION

For a correct and safe use of the safety light curtains of the SLIM series, the following points 
must be observed:

Please carefully read the instructions for the correct functioning before powering the light cur-
tain on.

CAUTION

Make sure that the protection level assured by the device (Type 2 or Type 4) is compatible with 
the real danger level of the machine to be controlled, according to EN ISO 13849-1 or EN

 

62061.

CAUTION

The failure to respect the safety distance reduces or cancels the ESPE protection function. For 
more detailed information about calculation of safety distance, please refer to the Instruction 
Manual.

Summary of Contents for SLIM

Page 1: ...roduct and enter the SLIM family name then select your product from the dropdown list Click on the Manuals Technical Literature link to download your Instruction Manual The Instruction Manual must be...

Page 2: ...g devices and not as command devices The machine must have its own START command The dimension of the smallest object to be detected must be larger than the resolution level of the device The ESPE mus...

Page 3: ...only depending on cable connection For cascaded system connection three Cascade Cables are available as accessory CS H1 03 B 001 CASCADE cable 0 1 m 90 95A252950 CS H1 03 B 005 CASCADE cable 0 5 m 49...

Page 4: ...configu ration pin connection in Instruction Manual Keep the receiver in a steady position and adjust the emitter until the 1 Yellow LED on the receiver is ON This condition shows the alignment of th...

Page 5: ...ed Lockout error F1 failure on microprocessor Internal Failure check for operating con dition see Technical data in Instruction Manual and any cause of electrical interference power cycle the ESPE F2...

Page 6: ...se of electrical interfer ence power cycle the ESPE F12 Cascade Failure Failure on cascade communica tion check cascade connection or terminator cap fixing see Cascade connection on page 2 F13 Failure...

Page 7: ...points of the standards listed in the Declaration of Conformity Datalogic products are mainly designed for integration purposes into more complex systems For this rea son it is under the responsibili...

Page 8: ...ght no part of this documentation may be reproduced stored in or introduced into a retrieval system or transmitted in any form or by any means or for any purpose without the express written permission...

Reviews: