QUICK REFERENCE GUIDE   

2

CONNECTIONS

EDM FBK /

SELECTION

Normally closed contact 
for a force-guided relay

EDM ENABLE

RESTART

Normally closed contact 
to 24 Vcc

MANUAL 
RESTART

OSSD1

EDM DISABLE

RESTART SELECTION

AUTOMATIC 
RESTART

FLOATING

ALIGN MODE

Cascade connection

Up to three SLIM light curtains can be connected in a cascade series. The cascade connection allows to monitor up to

 

three areas with only two Safety Outputs connected to Master unit. Master unit takes care of collecting safety optic 
scan results from Slave units and the synchronization between them to avoid mutual interference. 

Each SLIM unit can either be used as Master or Slave, only depending on cable connection

For cascaded system connection three Cascade Cables are available as accessory:

CS-H1-03-B-001

CASCADE cable 0.1 m

90

95A252950

CS-H1-03-B-005

CASCADE cable 0.5 m

490

95ASE2550

CS-H1-03-B-01

CASCADE cable 1 m

990

95ASE2560

To connect the cascade unit:

Fix all cascade units with proper brackets as described in par. “Mechanical Mounting” of the Instruction Man-
ual. (1)

Remove Terminator Caps at the end of Master and Slave 1 (if present) by loosening the two fixing screws for 
both emitter and receiver. (2)

Fasten the cascade cables in place of removed terminator caps, ensure all cables bend radius it’s not less than 
4mm (3)

Connect Slaves M12 male connectors to M12 Female connectors from cascade cables (4).

Receiver (RX)

Emitter (TX)

FUNCTION

CONNECTION TO

STATUS

FUNCTION

CONNECTION TO

STATUS

MODEL

DESCRIPTION

L +/- 10 (mm)

CODE

Summary of Contents for SLIM

Page 1: ...roduct and enter the SLIM family name then select your product from the dropdown list Click on the Manuals Technical Literature link to download your Instruction Manual The Instruction Manual must be...

Page 2: ...g devices and not as command devices The machine must have its own START command The dimension of the smallest object to be detected must be larger than the resolution level of the device The ESPE mus...

Page 3: ...only depending on cable connection For cascaded system connection three Cascade Cables are available as accessory CS H1 03 B 001 CASCADE cable 0 1 m 90 95A252950 CS H1 03 B 005 CASCADE cable 0 5 m 49...

Page 4: ...configu ration pin connection in Instruction Manual Keep the receiver in a steady position and adjust the emitter until the 1 Yellow LED on the receiver is ON This condition shows the alignment of th...

Page 5: ...ed Lockout error F1 failure on microprocessor Internal Failure check for operating con dition see Technical data in Instruction Manual and any cause of electrical interference power cycle the ESPE F2...

Page 6: ...se of electrical interfer ence power cycle the ESPE F12 Cascade Failure Failure on cascade communica tion check cascade connection or terminator cap fixing see Cascade connection on page 2 F13 Failure...

Page 7: ...points of the standards listed in the Declaration of Conformity Datalogic products are mainly designed for integration purposes into more complex systems For this rea son it is under the responsibili...