QUICK REFERENCE GUIDE
4
BASIC CONFIGURATION MODE
A. Keep
CONFIRM
button pressed to enter Basic Configuration Mode.
B. A
Test Pattern
is shown on led interface,
carefully check that all LEDs are lit
in sequence from 1 to 8,
then current configuration is shown.
C. Choose function to set by
SELECT
button, selected led blinks.
D. Configure selected function with
ENABLE
button (switch led on/off).
E. Repeat B-C steps until desired configuration is visualized.
F.
Keep
CONFIRM
button pressed to authorize the new configuration
SG4N model provides Muting and Override functions along with Automatic/Manual Restart and Exter-
nal Device Monitoring
.
Partial Muting
2
Zone (A)
Zone (A+B)
Zone (A+B+C)
Muting Exit Delay
3
ON
OFF
EDM
4
Enabled
Disabled
Restart Mode
5
Auto
Manual
Muting Direction
6
T (bidirectional)
L (monodirectional)
Muting Timeout
7
10 min
Inf.
Muting Filter
8
ON
OFF
CAUTION
The device can enter Basic Configuration during Normal Operation. As soon as CONFIRM action
after configuration is executed the device automatically restarts in Normal Operation with the
new configuration. Particular attention has to be taken during the basic configuration manage-
ment and use.
CAUTION
Muting time-out “
∞
” does not comply with the requirements of IEC 61496-1. Therefore, all
possible risks must be considered and related precautions undertaken before selecting the
“
∞
” option.
RX FUNCTION LIST IN MUTING (DEFAULT) OPERATION MODE (LED 3 ON YELLOW)
FUNCTION
LED #
SETTING
(default in bold)
LED STATUS
ESPE ZONES