background image

Summary of Contents for SG4 Extended

Page 1: ...G4 family name then select your product from the dropdown list Click on the Manuals Technical Literature link to download your Instruction Manual The Instruction Manual must be available at all times when installing and working with the product Scan or tap on the QR code to download the Instruction Manual SG4 Extended Series SG4 N Models QUICK REFERENCE GUIDE Safety Light Curtains with infrared be...

Page 2: ...ESPE must be installed in an environment complying with the characteristics indicated in chapter Techni cal data of the Instruction Manual The ESPE must not be installed close to strong and or flashing light sources in particular close to the front win dow of receiving unit The presence of intense electromagnetic disturbances could affect device s correct operation This condition shall be carefull...

Page 3: ...M12 8 poles M12 5 poles SG4 N RX 1 White RESTART RESET EDM OVERRIDE 2 Brown 24 VDC 3 Green MUTING 1 4 Yellow MUTING 2 5 Gray OSSD1 6 Pink OSSD2 7 Blue 0 V 8 Red MUTING LAMP SG4 N TX 1 Brown 24 V 2 White TEST 3 Blue 0 V 4 Black EARTH 5 N C ...

Page 4: ...dition shows the effective alignment of the first synchronisation beam B Rotate the emitter pivoting on the lower optics axis until the yellow SYNC 2 LED is OFF C Delimit the area in which alignment is good and steady through some micro adjustments for the first and then for the second unit so to have the maximum alignment LEVEL and then place both units in the center of this area D Fix the two un...

Page 5: ...ial Muting 2 Zone A Zone A B Zone A B C Muting Exit Delay 3 ON OFF EDM 4 Enabled Disabled Restart Mode 5 Auto Manual Muting Direction 6 T bidirectional L monodirectional Muting Timeout 7 10 min Inf Muting Filter 8 ON OFF CAUTION The device can enter Basic Configuration during Normal Operation As soon as CONFIRM action after configuration is executed the device automatically restarts in Normal Oper...

Page 6: ...or persists contact Datalogic Technical Support FAILURE LOCKOUT Failure on EDM Check EDM feedback line and EDM configu ration Activate RESET line FAILURE LOCKOUT Failure on restart Check RESTART line connection Activate RESET line FAILURE LOCKOUT BCM configuration failure Re operate Basic Configuration If error per sists contact Datalogic Technical Support CRITICAL FAILURE LOCKOUT Generic non rese...

Page 7: ... LOCKOUT Failure on optics Activate RESET line If error persists contact Datalogic Technical Support FAILURE LOCKOUT BCM Configuration failure Re operate Basic Configuration If error per sists contact Datalogic Technical Support CRITICAL FAILURE LOCKOUT Generic non resetta ble failure Turn ON OFF ESPE Shown Failure Code cor responds to failures above with steady LEDs ESPE WORKING MODE INDICATION L...

Page 8: ...nts of the standards listed in the Declaration of Conformity Datalogic products are mainly designed for integration purposes into more complex systems For this rea son it is under the responsibility of the system integrator to do a new risk assessment regarding the final installation Warning This is a Class A product In a domestic environment this product may cause radio interference in which case...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...right no part of this documentation may be repro duced stored in or introduced into a retrieval system or transmitted in any form or by any means or for any purpose without the express written permission of Data logic S p A and or its affiliates Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S and the E U www datalogic com 821005603 ...