Datalogic S70 Quick Start Manual Download Page 8

- Light SET 

  Sets a threshold a programmable % offset below the presented condition 

  Changes output state on any condition darker than the threshold condition 

  Threshold can be adjusted using "+" and "-" Navigation key (Manual Adjust) 

  Recommended for applications where only one condition is known, for example a stable light background with varying darker 

targets 

 See 

Program Mode

 for programming the Offset Percent setting 

 

A single sensing condition is presented, and the sensor positions a threshold a programmable % offset below the presented condition. When 
a condition darker than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting. 

 

Light SET (Light Operate shown) 

- Dark SET 

  Sets a threshold a programmable % offset above the presented condition 

  Any condition lighter than the threshold condition causes the output to change state 

  Threshold can be adjusted using "+" and "-" Navigation key (Manual Adjust) 

  Recommended for applications where only one condition is known, for example a stable dark background with varying lighter 

targets 

 See 

Program Mode 

on page 5 for programming the Offset Percent setting 

 

NOTE: Offset Percent MUST be programmed to Minimum Offset to accept conditions of no signal (0 counts). 

 

A single sensing condition is presented, and the sensor positions a threshold a programmable % offset above the presented condition. 
When a condition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting. 
 
 
 
 
 
 
 
 
 
 

Dark SET (Light Operate shown) 

- Calibration SET 

  Sets a threshold exactly at the presented condition 

  Threshold can be adjusted using "+" and "-" Navigation key (Manual Adjust) 

 

A single sensing condition is presented, and the sensor positions a threshold exactly at the presented condition. When a condition lighter 
than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO setting. 

 

 
 
 
 
 
 
 
 
 
 

Calibration SET (Light Operate shown) 

Summary of Contents for S70

Page 1: ...onnected to a terminal block 1 Analogue and Discrete Output LEDs 2 CH1 CH2 Switch 3 RUN PRG ADJ Mode Switch 4 Lever Action Fiber Clamp 5 Red Signal Level 6 Green CH1 Analog Output Signal or CH2 Thresh...

Page 2: ...these steps to install glass or plastic fibers 1 Open the dust cover 2 Move the fiber clamp forward to unlock it 3 Insert the fiber s into the fiber port s until they stop 4 Move the fiber clamp backw...

Page 3: ...is in the middle position All three button positions are used during PRG mode to navigate the display driven programming menu During ADJ mode SET is used to perform TEACH SET methods and are used to...

Page 4: ...s the following settings to be programmed in the S70 CH1 Analog Factory Default Settings Press and hold SET to exit choice list without saving 4 NOTE The CH1 settings programmed for rESP SPd inPt SEL...

Page 5: ...ted in Program mode the settings below can be configured for CH2 discrete output and are independent from CH1 settings CH2 Discrete Factory Default Settings Press and hold SET to exit choice list with...

Page 6: ...on to 5 V 20 mA The order of the taught points determines the slope If the first taught condition is darker the slope will be positive If the first taught condition is lighter the slope will be negati...

Page 7: ...threshold at the optimum level see Fig 3 Dynamic TEACH Light Operate shown Reverse the CH2 Output ON and OFF conditions by using the LO DO Light Operate Dark Operate selection through the program int...

Page 8: ...tate Threshold can be adjusted using and Navigation key Manual Adjust Recommended for applications where only one condition is known for example a stable dark background with varying lighter targets S...

Page 9: ...at 30 VDC ON state saturation voltage NPN 1 5 V PNP 2 V Analogue Output Recovery Time 2 the selected response speed Analogue Output Ripple Content p p 0 5 of the full scale analogue output Analogue O...

Page 10: ...talogic S r l Via S Vitalino 13 40012 Calderara di Reno Italy Tel 39 051 3147011 Fax 39 051 3147205 www datalogic com Datalogic reserves the right to make modifications and improvements without prior...

Reviews: