Datalogic S70 Quick Start Manual Download Page 1

 

S70 Analogue Output 

Advanced sensor with dual digital displays 

for use with plastic and glass fiber optic assemblies 

 

For complete technical information about this product, including dimensions, accessories, and specifications, see 

www.datalogic.com

 

 

 

 Figure 

 

 

 

Model

 

Sensing Beam Color

 

Reference Sensing Range

1

 

Outputs

 

Connector

 

S70-5-E3-PV/NV 

Visible Red 

2250 mm 

Voltage and PNP or 

NPN 

Discrete 

4-pin,  

M8 Pico-style 

S70-5-E3-PI/NI 

Current and PNP or 

NPN 

Discrete 

1

 

NOTE: Maximum sensing range in opposed mode at 12 ms response speed using 1mm diameter core plastic fiber. 

 

CONNECTIONS

 

 

NPN Version 

PNP Version 

 

 

 

 

 

NOTE:  Open lead wires must be connected to a terminal block. 

 

1

 

Analogue and Discrete Output LEDs 

2

 

CH1/CH2 Switch 

3

 

RUN/PRG/ADJ Mode Switch 

4

 

Lever Action Fiber Clamp 

5

 

Red Signal Level 

6

 

Green CH1 Analog Output 
Signal or CH2 Threshold 

7

 

+/SET/- Navigation key 

Key 

1 = Brown 
2 = White 
3 = Blue 
4 = Black 

WARNING: Not to be used for personnel protection

 

Never use this device as a sensing device for personnel protection. 
Doing so could lead to serious injury or death. 

This device does not include the self-checking redundant circuitry 

necessary to allow its use in personnel safety applications. 
A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. 

LOAD 

 

LOAD 

A_Out 

 

D_Out

 

Input wire

 

      

+

 

10-30 VDC (Current models) 
12-30 VDC (Voltage models) 
 

 

 

 


 

LOAD 

 

LOAD 

A_Out 

 

D_Out

 

Input wire

 

      

+

 

10-30 VDC (Current models) 
12-30 VDC (Voltage models) 

 

 

 


 

Summary of Contents for S70

Page 1: ...onnected to a terminal block 1 Analogue and Discrete Output LEDs 2 CH1 CH2 Switch 3 RUN PRG ADJ Mode Switch 4 Lever Action Fiber Clamp 5 Red Signal Level 6 Green CH1 Analog Output Signal or CH2 Thresh...

Page 2: ...these steps to install glass or plastic fibers 1 Open the dust cover 2 Move the fiber clamp forward to unlock it 3 Insert the fiber s into the fiber port s until they stop 4 Move the fiber clamp backw...

Page 3: ...is in the middle position All three button positions are used during PRG mode to navigate the display driven programming menu During ADJ mode SET is used to perform TEACH SET methods and are used to...

Page 4: ...s the following settings to be programmed in the S70 CH1 Analog Factory Default Settings Press and hold SET to exit choice list without saving 4 NOTE The CH1 settings programmed for rESP SPd inPt SEL...

Page 5: ...ted in Program mode the settings below can be configured for CH2 discrete output and are independent from CH1 settings CH2 Discrete Factory Default Settings Press and hold SET to exit choice list with...

Page 6: ...on to 5 V 20 mA The order of the taught points determines the slope If the first taught condition is darker the slope will be positive If the first taught condition is lighter the slope will be negati...

Page 7: ...threshold at the optimum level see Fig 3 Dynamic TEACH Light Operate shown Reverse the CH2 Output ON and OFF conditions by using the LO DO Light Operate Dark Operate selection through the program int...

Page 8: ...tate Threshold can be adjusted using and Navigation key Manual Adjust Recommended for applications where only one condition is known for example a stable dark background with varying lighter targets S...

Page 9: ...at 30 VDC ON state saturation voltage NPN 1 5 V PNP 2 V Analogue Output Recovery Time 2 the selected response speed Analogue Output Ripple Content p p 0 5 of the full scale analogue output Analogue O...

Page 10: ...talogic S r l Via S Vitalino 13 40012 Calderara di Reno Italy Tel 39 051 3147011 Fax 39 051 3147205 www datalogic com Datalogic reserves the right to make modifications and improvements without prior...

Reviews: