background image

 

 

 

 

This product is covered by one or more of the following patents. 

DE202014007924.2U9; IT280386; EP1148346B1 

(see www.patents.datalogic.com for patent list) 

 

 

S65-PA-5-M13-OOI 

Time-of-flight infrared background suppression sensor with current 
analog output 

S65-PA-5-M13-OOV 

Time-of-flight infrared background suppression sensor with voltage 
analog output 

 

INSTRUCTION MANUAL 

 

SIGNALS 

OUTPUT LED (yellow) 

Yellow  LEDs  on,  numbered  as  1  and  2, 
indicate activation of Q1 and Q2 outputs. 
LEDs blink at the same time if measurement is 
out  of  range  or  not  available  due  to  the 
presence of environmental contamination. 

POWER LED (green) 

Green PWR LED on indicates that the device is switched on and operating. 

ACTIVE SETUP LED (green) 

Green PNP/NPN LEDs on indicate that the device is in the selected setup. 

 

OUTPUT  and  POWER  LEDS  also  indicate  setup  settings 

(see  “Setup” 

chapter). 

 

INSTALLATION 

Sensor  can  be  installed  by  means  of  the  two  through  holes  present  on  the 
body,  using  screws  (M4x35  or  longer;  max.  tightening  torque:  1Nm)  with 
washers and nuts. 
If mating surface is not perfectly flat, a bracket is recommended. 
Various  adjustable  brackets  are  available  to  help  sensor  positioning  (see 
accessories on the catalogue). Operating distance is measured from the front 
surface of the sensor optics. 
M12  connector  can  be  aimed  in  two  different  ways,  by  working  the  relevant 
retaining spring and turning the unit by 90° until it stops. 

 

 

1)

 

Connect and fasten M12 connector when power is off. 

2)

 

Connect power cable and/or I/O as indicated for every model. 

3)

 

Fasten  sensor  to  suitable  support,  making  sure  to  first  align  the  green 
pointer at the centre of the target 

4)

 

Sensor function will be available in a few seconds from switch-on. 

5)

 

Allow warm-up time before starting normal operations. 

 

CONNECTIONS 

S65-PA-5-M13-OOI    

 
 
 
 
 
 
 
 

S65-PA-5-M13-OOV 
 
 
 
 
 

 
 
 
 
NOTE: Wire colour refers to European standard. 

S65-PA-5-M13 ADJUSTMENT 

1.  Set up the device as needed. Press SET1+SET2 > 3 sec until the 3 green LEDs 

blink to enter the setup menu. 
-  Press SET 2 to navigate within the menu until output 

 

→

 

→

 

-  Press SET 1 to select setup. 
-  Press SET1 and SET2 > 6 sec to go back to default 

setup. The new configuration will be saved only when 
exit  to  the  menu.  The  sensor  system  will 
automatically  reset  to  the  original  configuration  if  a 
new configuration is not detected within 10 seconds. 

2.  Select  hysteresis  according  to  the  application, 

considering  the  environmental  and  the  more  critical 
operating conditions. 

3.  Identify the target reading point using the green visible 

pointer  by  pressing  SET1  (or  SET2)  for  1  sec  <  t  <  3 
sec (the pointer will remain active for 5 sec). 

4.  Make sure that the spot is inside the target surface to be acquired. 
5. 

Target Acquisition:

 Press SET1 (or SET2) > 3sec to teach-in switching point 1 or 

2 until the yellow LED Q1 (or Q2) flashes. 
 

NOTE:

 a spot partialization could change detection performances.

 

READING AREA DIMENSIONS

 

Typical spot size 

– squared section 

 

 

 
 

SETUP 

MODE menu

 

 

PNP/NPN

 

 

LIGHT/DARK

 

 

HYSTERESIS

 

 

 

 

 

Press SET1+SET2 for t > 3 sec, until all 3 

green LEDs are flashing. Releasing the 

buttons, the sensor enters MODE menu. 

Press SET2 to navigate within the menu 

(

→→

), press SET1 to select setup. 

Q1 ON = 

Setup 

PNP 

Q2 ON = 

Setup 

NPN 

Q1 ON = 

setup 

LIGHT 

Q2 ON =  

setup 

DARK 

Q1 ON = 

80 mm 

hysteresis 

Q2 ON = 

50 mm 

hysteresis 

Q1+Q2 ON = 

30 mm 

hysteresis 

for both outputs 

(

NPN is not  

available during I/O Link communication)

 

for both outputs 

 

for both outputs 

 

Restore Default Setup

 

Green Pointer

 

Teach-In

 

Key 

 

 

 

 

 

 

Status LED negligible 

 

LED OFF 

 

Steady LED 

 

LED ON and flashing

 

Press SET1 + SET2 for at least 6 sec; before 

default setup there is a temporary darkening of 

all LEDs, after which it is possible to release 

the buttons. 

 

Press SET1 (or SET2) for 1 sec. < t < 3 sec 

to switch on the green pointer 

 

Point the target. Press SET1 (or SET2) > 3 sec 

until Q1 (or Q2) blinks, then release button to 

acquire the target 

 
 

TECHNICAL DATA 

 

S65-PA-5-M13-OOI 

S65-PA-5-M13-OOV 

Supply voltage: 

24 VDC ± 20% 

Consumption: 

< 2.2 W (excluding any loads) 

Analog output: 

4-20mA scalable ((VDC-2V)/20mA max.)) 

0-10V scalable (1000 

Ω

 min.) 

Operating distance: 

0.3..5 m (90% white) /        0.3..4.5 m (18% grey) /     0.3..3.5 m (6 % black) 

Min. teach distance: 

400 mm 

Hysteresis: 

30mm / 50mm / 80mm 

Response time: 

8.5 msec max. 

Resolution: 

10 mm 

Thermal compensation error: 

1.5 mm /°C (T 

≠ 25°C) 

Switching output: 

Can be set up (PNP NPN / Light Dark) 100mA max. 

Warming-up time: 

20 min typ 

Warnings: 

Q1 (YELLOW) / Q2 (YELLOW) / ON PWR (GREEN) - PNP / NPN (GREEN) 

Operating temperature: 

-

15°… +55 °C (with device ON)  

Storage temperature: 

-

25 … +70 °C 

Electrical strength:  

500 VAC, 1 min between electronics and case 

Insulation resistance: 

> 20 M

, 500 VDC between electronics and case 

Reading spot size: 

typ 100x100 mm @ 5m  

Pointer spot size (green): 

typ 200x200 mm @ 5m 

Max. deviation of pointer/reading spot axes origin: 

+/- 40 mm  

Emission and Wavelength: 

LED / 850 nm 

Ambient light rejection: 

according to EN 60947-5-2,  

Vibrations: 

width 0.5 mm, frequency 10 … 55Hz, per axis (EN60068-2-6) 

Shock resistance: 

11 ms (30 G) 6 shocks for each axis (EN60068-2-27) 

Humidity: 

< 90% no condensation 

Exposed material: 

Body: ABS  /   Display: POLYESTER 

Front side material: 

PMMA 

Mechanical protection: 

IP67 

Connections: 

M12 - 5 poles 

(Overall) Dimensions: 

50 x 50 x 25 mm 

Weight: 

50 g.max. 

UL (requirements): 

Class 2 power supply according to UL 508  

 

Factory settings and default settings are (for both Q1 and Q2): PNP OUT, LIGHT mode, Switching distance 2 m, hysteresis = 80mm, distance_min(D1) = 300 mm, distance_max (D2) = 5000 mm 

 

 

OVERALL DIMENSIONS 

 

 

SAFETY WARNINGS

 

All the regulations and rules concerning electric and mechanical safety must be complied 
with during sensor operation. 
The sensor must be protected against mechanical damage. 
This product is only for indoor use. 

 

MAINTENANCE

 

This device requires no special maintenance operations.  
At any rate, take care to clean the optics surface with a compatible detergent in order to 
avoid degraded performance. 
Use protections for the plastic parts in case of dangerous environment. 

 

ANALOG OUTPUT 

 

 

 

 

 

 

 

Scalable output: select MIN & MAX values of distance 

 

 

 

 

 

D1<D2 

 positive slope 

 

 D1>D2 

 negative slope 

 

 

 

 

Point the target. Press SET1 for t > 6 sec until Q1 stops blinking, then release button to 
acquire the distance D1. Press SET2 for t > 6 sec until Q2 stops blinking, then release 
button to acquire the distance D2. Distance is 0 if out of operating range. 

 

The sensors are NOT safety devices, and so MUST NOT be used in the safety control of 

the machines where installed.

 

Datalogic S.r.l. 

Via S. Vitalino 13 - 40012 Calderara di Reno - Italy 
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com

 

Helpful links at www.datalogic.com: 

Contact Us,

 

Terms and Conditions,

 

Support

 

 

For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please 
refer to the website a

www.datalogic.com

 
©  2021  Datalogic  S.p.A.  and/or  its  affiliates 

  ALL  RIGHTS  RESERVED. 

  Without  limiting  the  rights 

under copyright, no part of this documentation may be reproduced, stored in or introduced into a retrieval 
system,  or  transmitted  in  any  form  or  by  any  means,  or  for  any  purpose,  without  the  express  written 
permission  of  Datalogic  S.p.A.  and/or  its  affiliates.  Datalogic  and  the  Datalogic  logo  are  registered 
trademarks  of  Datalogic  S.p.A.  in  many  countries,  including  the  U.S.A.  and  the  E.U.  All  other  trademarks 
and  brands  are  property  of  their  respective  owners.  Datalogic  reserves  the  right  to  make  modifications 
and improvements without prior notification. 
 

821007533 Rev. D 

 

   

                                            

                               

    

    

    

    

   

 

  

   

   

   

   

 

 

 

 

  

  

 

    

 

                        
                           
                     

1 (BROWN) : +24 V ±

 

2 (WHITE)    : Q2 100mA max.

 

3 (BLUE)       : 0 V

 

4 (BLACK)     : Q1 100mA max.

 

5 (GREY)       : Current Analog Output 4-20mA

 

1 (BROWN) : +24 V ±

 

2 (WHITE)    : Q2 100mA max.

 

3 (BLUE)       : 0 V

 

4 (BLACK)     : Q1 100mA max. 

 

5 (GREY)       : Current Voltage Output 0-10V

 

t > 6 sec 

1 sec < t < 3 sec 

t > 6 sec 

t > 3 sec 

Reviews: