S62 SERIES
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (yellow) (S62..A/B/C/F)
The yellow LED ON indicates the output status.
STABILITY LED (green) (S62..A/B/C/F)
The green LED permantely ON indicates a stable operating
condition, where the signal received has a safety margin
higher than 30% respect to the output switching value.
The sensor is ready to function correctly.
POWER ON LED (green) (S62..G)
The green LED ON indicates the powering status and the laser
emission presence.
SENSIBILITY TRIMMER (ADJ.) (S62..A/B/C/F)
A mono-turn trimmer adjusts the sensitivity and the sensor
operating distance.
Please refer to “SETTING” paragraph for the correct use
procedure.
DARK/LIGHT TRIMMER (S62..RX/PN)
The LIGHT/DARK mode is selected using a mono-turn
trimmer.
LIGHT MODE: clockwise rotation
DARK MODE: counter-clockwise rotation.
WARNING: the maximum mechanical rotation range of the
trimmer is 240°. Do not force over of the maximum and
minimum positions.
CONNECTIONS
DC models:
S62-PA-2/5-PN
S62-PA-2/5-PP/NN S62-2/5-G
AC models:
S62-PA-1-A/B/C/F S62-PA-1-G
TECHNICAL DATA
S62-PA-2/5 S62-PA-1
Power supply:
10 … 30 VDC– Class 2 (UL508)
24…240 VAC / 24…60 VDC
Ripple:
2 Vpp max.
10 % max
Current consumption
(output current excluded):
< 30 mA
< 3 VA
Outputs:
S62..PP/NN:
PNP or NPN N.A./N.C.
30 VDC
S62..PN:
NPN/PNP; 30 VDC max
(short-circuit protection)
Electromechanical SPDT
250 VAC / 30 VDC
Output current:
100 mA max
(overload and overvoltage protection)
2 A max.
(resistive load)
Output saturation voltage:
2 V
-
Response time:
S62…A/B/C:
500
s max.
S62…F/G:
1
ms
25 ms
Switching frequency:
S62…A/B/C:
1 kHz
S62…F/G:
500Hz
20Hz
Emission type:
RED (640 nm) (S62..A/B/C/G)
Operating distance (typical values):
S62...B:
0.1…8 m on R2 (Ø63 mm reflector) (EG = 2)
S62…A:
13m on R2 (Ø63 mm reflector) (EG = 2)
S62...C01:
90 cm on 90% White target (EG = 2)
S62...C11:
200 cm on 90% White target (EG = 2)
S62…F/G:
0…25 m
Indicators:
S62…A/B/C/F:
OUTPUT LED (YELLOW) / STABILITY LED (GREEN)
S62…G:
POWER ON LED (GREEN)
Adjustment:
Mono-turn sensitivity adjustment trimmer
Mono-turn light/dark trimmer (S62..RX/PN)
Operating temperature:
-10 … 55 °C
Storage temperature:
-20 … 70 °C
Dielectric strength:
500 VAC, 1 min between electronics and housing
Insulating resistance:
> 20 M
, 500 VDC between electronics and housing
Ambient light rejection:
according to EN 60947-5-2
Vibrations:
0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6)
Shock resistance:
11 ms (30 G) 6 shock for every axis (EN60068-2-27)
Housing material:
ABS
Lens material:
PMMA window, policarbonate lens
Mechanical protection:
IP67
Connections:
2 m cable
4 mm / M12 4-pole connector
2 m cable
5 mm
UL requirements:
VDC models: they are intended to be connected to a Class 2 transformer or class
2 power supply. VAC models: these devices shall be connected to a power-
supply or system,including filters or air-gaps, of overvoltage category II
(“load level – secondary circuit of a protected utility transformer”), suitable to
control over-voltages at the maximum “rated impulse withstand voltage peak of
1.2KV and with a short-circuit power limit at max 500VA.
Weight:
90 g. max. cable versions / 40 g. max. connectors versions
SETTINGS
S62..A/B setting:
Position the sensor and reflector on opposite sides. Turn the sensitivity trimmer to maximum.
Find the points where the yellow LED (OUT) in both vertical and horizontal positions and fix the sensor in the centre
between these points. Optimum operation is obtained when both LEDs switch ON. If necessary, reduce sensitivity using the
trimmer, in order to detect very small targets. In order to improve alignment, repeat the procedure detailed above whilst
progressively reducing the sensitivity.
S62..C setting:
Position the sensor and turn the sensitivity trimmer at minimum: the yellow LED is OFF
(litgh mode). Place the target opposite the sensor. Turn the sensitivity trimmer clockwise until the yellow LED
turns ON (Target detected state, pos.A). Remove the target, the yellow LED turns OFF.
Turn the trimmer clockwise until the yellow LED turns ON (Background detected state, pos.B).
The trimmer reaches maximum if the background is not detected. Turn the trimmer in intermediate position C,
between the two positions A and B. The green LED must be ON.
S62…F/G setting:
Position the sensors on opposite sides. Turn the sensitivity trimmer to maximum. Find the points where
the yellow LED (OUT) is switched ON and OFF in both vertical and horizontal positions, and fix the sensor in the centre
between these points. Optimum operation is obtained when both LEDs switch ON.
If necessary, reduce sensitivity using the trimmer, in order to detect very small targets.
In order to improve alignment, repeat the procedure detailed above whilst progressively reducing the sensitivity.
DIMENSIONS
INSTALLATION
The sensor can be positioned by
means of the two housing holes
using two screws (M4x35 or longer,
1.2Nm maximum tightening
torque).
Various orientable fixing brackets to
ease the sensor positioning are
available (please refer to the accessories listed in the general
catalogue). The operating distance is measured from the front
surface of the sensor optics. The M12 connector can be oriented
at two different positions using the specific fastening spring and
rotating the block of 180°.
TEST FUNCTION (S62...G)
The TEST+ and TEST- inputs can be used to switch off the
emitter light and verify that the system is correctly operating: the
receiver output should switch when the test is activated while the
beam is uninterrupted: the inputs activating voltage range is
12…30 VDC, respecting the polarity.
The emission is switched OFF connecting TEST+ to VDC and
TEST- to 0V.
The sensors are NOT safety devices, and so MUST NOT be used in the
safety control of the machines where installed.
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com:
Contact Us,
Terms and Conditions,
Support
.
The warranty period for this product is 36 months. See General Terms and
Conditions of Sales for further details.
Under current Italian and European laws, Datalogic is not obliged to
take care of product disposal at the end of its life. Datalogic
recommends disposing of the product in compliance with local laws or
contacting authorised waste collection centres.
© 2007 - 2017 Datalogic S.p.A. and/or its affiliates
ALL RIGHTS
RESERVED.
Without limiting the rights under copyright, no part of this
documentation may be reproduced, stored in or introduced into a retrieval
system, or transmitted in any form or by any means, or for any purpose,
without the express written permission of Datalogic S.p.A. and/or its affiliates.
Datalogic and the Datalogic logo are registered trademarks of Datalogic
S.p.A. in many countries, including the U.S.A. and the E.U. All other
trademarks and brands are property of their respective owners. Datalogic
reserves the right to make modifications and improvements without prior
notification.
821002352 Rev. C
MIN
MAX
A
B
C
RELAY