S62-PL…B Laser
Polarised retroreflex
S62-PL…C Laser
Diffuse proximity
INSTRUCTION MANUAL
S62..B S62..C
CONTROLS
OUTPUT LED (yellow)
The yellow LED ON indicates the following output status: N.O.
closed and N.C. open.
POWER ON LED (green)
The green LED ON indicates the sensor powering status and
laser emission presence.
SENSITIVITY TRIMMER (ADJ.)
Monoturn trimmer that adjusts the sensitivity and thus the
sensor operating distance.
Please refer to “SETTING” paragraph for the correct use
procedure.
WARNING: the maximum mechanical trimmer rotation is
equal to 240°. Do not apply excessive torque over the
maximum and minimum positions.
INSTALLATION
The sensor can be positioned by
means of the three housing’s
holes using two screws (M4x25
or longer, 1.5 Nm maximum
tightening torque) with washers.
Various orientable fixing brackets
to ease the sensor positioning
are available (please refer to the accessories listed in the
general catalogue).The operating distance is measured from
the front surface of the sensor optics.
The M12 connector can be oriented at two different positions
using the specific fastening spring and rotating the block to
180°.
CONNECTIONS
M12 connector
TECHNICAL DATA
S62..B S62..C
Power supply:
10 … 30 Vcc
Ripple:
2 Vpp max.
Consumption
(output current excluded):
30 mA max
Outputs:
PNP or NPN N.O. / N.C.; 30 Vdc max. (short-circuit protection)
Output current:
100 mA max (overload and overvoltage protection)
Output saturation voltage:
2 V
Response time:
200
s
Switching frequency:
2.5 kHz
Emission type:
RED LASER Class 1
EN 60825-1 (2014)
RED LASER (
= 645…665 nm): Class 2 EN 60825-1 (2014)
Class II CDRH 21 CFR PART 1040.10Pulsed emission: pot.
max
5 mW; pulse duration = 5
s; frequency max = 32 KHz
Operating distance (typical values):
refer to TAB.1
1m on 90% white target (EG2)
Min. detectable object dimension:
0.5 mm at 0.5m (minimum spot)
Indicators:
OUTPUT LED (YELLOW) / POWER ON LED (GREEN)
Setting: Monoturn
sensitivity adjustment trimmer
Functioning temperature:
-10 … 55 °C
Storage temperature:
-20 … 70 °C
Dielectric strength:
500 Vac 1 min., between electronics and housing
Insulating resistance:
>20 M
500 Vdc, between electronics and housing
Ambient light rejection:
according to EN 60947-5-2
Vibrations:
0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6)
Shock resistance:
11 ms (30 G) 6 shock for every axis (EN60068-2-27)
Housing material:
ABS
Lens material:
PMMA window, polycarbonate lenses
Mechanical protection:
IP67
Connections:
M12 4-pole connector
Weight:
40 g. max.
S62…B SETTING
S62…B alignment:
- Position the sensor and reflector aligned on opposite sides at the desired distance.
- Turn to maximum the sensitivity adjustment trimmer (ADJ.) (clockwise).
- Determine the powering on and powering off points of the yellow LED (OUT) by moving
vertically and horizontally the sensor and mount the
sensor in the middle of the points found.
Control:
-
Enter laterally the object inside the operating
field
and control that the yellow LED turns on.
-
Remove the object and check that the yellow
LED
turns off immediately
S62…C setting:
Position the sensor and turn the sensitivity trimmer at minimum: the yellow LED is OFF. Place the target opposite
the sensor.
Turn the sensitivity trimmer clockwise until the yellow LED turns ON (Target detected state, pos.A).
Remove the target, the yellow LED turns OFF. Turn the trimmer clockwise until the yellow LED turns ON (Background detected
state, pos.B). The trimmer reaches maximum if the background is not detected.
Turn the trimmer in intermediate position C, between the two positions A and B. The green LED must be ON.
S62…B PERFORMANCES
TAB.1: Operating distances (m)
REFLECTOR (mm)
R1 (Ø31)
R2 (Ø63)
R6 (60x40)
R7 (51X51)/
R20 (Ø63)
R8
(19X10)
0.3 … 16
0.3 … 20
0.4 … 22
0.3 … 22
0.2 … 2
Note
: The use of the RT 3970 reflecting tape is not suggested.
DIMENSIONS
18x
45°
50
42
11
SENSITIVITY TRIMMER
10.7
POWER ON LED
OUTPUT LED
25
6.18
mm
6
14
Ø15
16
M12
42
1.1
50
2
0.75
18
4.7
21.5
8.5
RECEIVER
EMITTER
SAFETY PRECAUTIONS
All the electric and mechanical safety regulations have to be
respected during sensor functioning.
The sensor has to be protected against mechanical damage.
Apply the labels supplied in a visible position near the laser
emission beam.
S62..C:
Do not stare directly into the laser beam!
Do not point the laser beam towards people!
Eye irradiation superior to 0.25 seconds is dangerous.
Please refer to the Class 2 Standard (EN60825-1).
These sensors can not be used for safety applications!
The sensors are NOT safety devices, and so MUST NOT be used
in the safety control of the machines where installed.
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com:
Contact Us,
Terms and Conditions,
Support
.
The warranty period for this product is 36 months. See General Terms and
Conditions of Sales for further details.
Under current Italian and European laws, Datalogic is not obliged to take
care of product disposal at the end of its life. Datalogic recommends
disposing of the product in compliance with local laws or contacting
authorised waste collection centres.
© 2008 - 2017 Datalogic S.p.A. and/or its affiliates
ALL RIGHTS
RESERVED.
Without limiting the rights under copyright, no part of this
documentation may be reproduced, stored in or introduced into a retrieval
system, or transmitted in any form or by any means, or for any purpose,
without the express written permission of Datalogic S.p.A. and/or its affiliates.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A.
in many countries, including the U.S.A. and the E.U. All other trademarks and
brands are property of their respective owners. Datalogic reserves the right to
make modifications and improvements without prior notification.
826003257 Rev. H
spot diameter (mm)
distance (mm)
MIN
MAX
A
B
C
CLASS 1 EN 60825-1
(2014)
LASER PRODUCT
CLASS 2 EN 60825-1
(2014)
LASER PRODUCT