background image

 

 
 
 

 

S62…M 

Background suppression

 

INSTRUCTION MANUAL 

 

CONTROLS 

OUTPUT LED (yellow) 

The yellow LED ON indicates that the N.O. output is closed and the N.C. 
output is open. 

STABILITY LED (green) (S62…M2/M3) 

When permanently ON, the green LED indicates a normal operating condition 
where the received signal has a safety margin superior to 30% respect to the 
output switching value. The sensor is ready to function correctly (stability 
condition). 

POWER ON LED (green) (S62…M0/M1) 

The green LED ON indicates the powering status and the laser emission 
presence. 

DISTANCE ADJUSTMENT TRIMMER (ADJ.) 

A 6-turn trimmer allows the background suppression distance adjustment 
through a mechanical variation of the optic triangulation angle. 
The operating distance increases, rotating the screws in a clockwise direction. 
Please refer to the “SETTING” paragraph for acquisition or setup procedure 
indications. 

POSITION INDICATOR 

This indicator presents a scale numbered from 1 to 6 that allows a precise 
adjustment of the suppression distance in the entire operating range. 
Please refer to the “SETTING” paragraph for use indications. 

TIMER ADJUSTMENT TRIMMER (S62…M05/M15/M25/M35) 

This control allows to vary the output delay deactivation from 0 to 1 sec. 
Please refer to “TIMER FUNCTIONS” paragraph for use indications. 

DARK/LIGHT TRIMMER (S62…M01/M11-PN) 

The LIGHT/DARK mode is selected using a mono-turn trimmer. 
LIGHT MODE: clockwise rotation 
DARK MODE: counter-clockwise rotation. 

WARNING:  the maximum mechanical rotation range of the trimmer is 240°. 
Do not force over of the maximum and minimum positions. 

INSTALLATION 

The sensor can be positioned by means 
of the three housing’s holes using two 
screws (M4x25 or longer, 1.5Nm max. 
tightening torque) with washers. 
Various orientable fixing brackets to 
ease the sensor positioning are available 
(please refer to the general catalogue). 
The operating distance is measured 
from the front surface of the sensor 
optics. 
The M12 connector can be oriented at two different positions using the 
specific fastening spring and rotating the block of 180°. 
 

CONNECTIONS 

S62-PA-2/5…PN 

 

 

S62-PA-2…PP/NN 

 

 

S62-PA-5…PP/NN (M12 connector) 

 

 

 

 

TECHNICAL DATA 

 

S62…M0-PP/PN/NN

S62…M1-PP/PN/NN

S62…M2-PP/PN/NN

S62…M3-PP/PN/NN 

Power supply: 

10 … 30 VDC 

Ripple: 

2 Vpp max. 

Consumption 
(output current excluded): 

40 mA max. 

Outputs: 

S62...PP/NN:

 PNP or NPN N.A./N.C. 30 VDC  /  

S62...PN:

  NPN/PNP; 30 VDC max (short-circuit protection) 

Output current: 

100 mA (overload and overvoltage protection) 

Output saturation voltage: 

 2 V 

Response time: 

500 

1 ms 

1,5 ms 

Switching frequency: 

1 kHz 

500 Hz 

330 Hz 

Emission type: 

RED (660 nm) 

INFRARED (880 nm) 

Spot dimension: 

6x6 mm (at 200 mm) 

15x15 mm (at 400 mm) 

200x200 mm (at 2000 mm) 

Operating distance (typical values): 

30…300 mm 

60…600 mm 

60…1200 mm 

200…2000 mm 

(recommended target 400x400mm) 

Adjustment: 

Multiturn distance adjustment trimmer / Timer adjustment trimmer (S62…M05/M15/M25/M35) 

DARK/LIGHT selection: 

mono-turn trimmer (S62…M01/M11-PN) 

Difference (90% white / 4% black): 

< 8 % 

< 12 % 

< 25 % 

< 30 % 

Hysteresis (90% white): 

< 5 % 

< 20 % 

Indicators: 

OUTPUT LED (YELLOW) / STABILITY LED (GREEN) 

OUTPUT LED (YELLOW) / POWER ON LED (GREEN) 

Operating temperature: 

-10 … 55 °C 

Storage temperature: 

-20 … 70 °C 

Dielectric strength: 

500 VAC 1 min., between electronics and housing 

Insulating resistance: 

>20 M

 500 VDC, between electronics and housing 

Ambient light rejection: 

According to EN 60947-5-2 

Vibrations: 

0.5 mm amplitude, 10 … 55 Hz frequency, for each axis (EN60068-2-6) 

Shock resistance: 

11 ms (30 G) 6 shock for each axis (EN60068-2-27) 

Housing material: 

ABS 

Lens material: 

PMMA window; PC lens 

Mechanical protection: 

IP67 

Connections: 

2 m cable 

 4 mm / M12 4-pole connector 

UL requirements: 

they are intended to be connected to a Class 2 transformer or class 2 power supply 

Weight: 

90 g. max. cable vers. / 40 g. max. connector vers.  

 

SETTING 

Suppression distance setting 

 

1. 

Object detection

 

Position object to detect in front of the sensor at the distance required. 
Turn distance adjustment trimmer (ADJ) to minimum: yellow LED OFF and 
green LED ON. 
 

 

 

Rotate trimmer in a clockwise direction until the yellow LED and green LED 
turn ON. 

Object detection condition

 (A status of position indicator)

 

 

 

 

  

A

 

 

2. 

Background suppression

 

Remove object and ensure that the background is in front of the sensor: 
yellow LED OFF and green LED ON. 
 

 

 

Rotate trimmer in a clockwise direction until the yellow LED and green LED 
turn ON: 

background detection condition 

(B status of position indicator).

 

 

 

 

  

 

The trimmer reaches maximum level with yellow LED OFF if the background 
is outside the operating range. 

 

 
Rotate trimmer in an anticlockwise direction until yellow LED turns OFF 
and green LED ON: 

condition where background is outside operating 

range 

(C status of position indicator). 

 

 

   

3. Setting and control 

Rotate trimmer in an anticlockwise direction until the indicator reaches 
an intermediate point between position A and C. 

 

 

If position A and C are close to each other, leave trimmer on position C. 
The sensor is now ready to function correctly and in stable conditions:

 

 

 

DETECTION DIAGRAM

 

 

 
 

DIMENSIONS 

Ø4

18.4

11

14

POSITION INDICATOR

DISTANCE ADJUSTMENT TRIMMER

OUTPUT LED

STABILITY LED

10.7

mm

42

50

6

11

6.18

TIMER ADJUSTMENT

TRIMMER (mod.M05/M15/M25/M35)

M12

Ø15

14

CABLE VERSION

18

x45°

16

42

50

0.

7

5

1.1

2

18

4.7

EMITTER

RECEIVER

18.2

15

.5

 

 
 

TIMER FUNCTION (S62…M05/M15/M25) 

The timer function allows to adjust the output deactivation delay when the 
object is outside the detection area. The delay extends the output activation 
allowing the slower interface systems to detect shorter pulses. 
 

 

 
The delay adjustment is carried-out manually using the Timer adjustment 
trimmer. Clockwise rotation increase the delay from 0 to a max. 1 sec. value. 

 

 

 

The sensors are NOT safety devices, and so MUST NOT be used in the safety control of the machines 

where installed. 

 

 

Datalogic S.r.l. 

Via S. Vitalino 13 - 40012 Calderara di Reno - Italy 
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com

 

 
Helpful links at www.datalogic.com: 

Contact Us,

 

Terms and Conditions,

 

Support

 
The warranty period for this product is 36 months. See General Terms and Conditions of Sales for 
further details. 
 

 

Under current Italian and European laws, Datalogic is not obliged to take care of product 
disposal at the end of its life. Datalogic recommends disposing of the product in compliance with 
local laws or contacting authorised waste collection centres. 

 
© 2007 - 2017 Datalogic S.p.A. and/or its affiliates 

 ALL RIGHTS RESERVED. 

 Without limiting the 

rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a 
retrieval system, or transmitted in any form or by any means, or for any purpose, without the express 
written permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic logo are registered 
trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks 
and brands are property of their respective owners. Datalogic reserves the right to make modifications 
and improvements without prior notification. 

 

826002875 Rev. G 

DARK/LIGHT 
TRIMMER 
(S62-M01/M11-PN) 

STABILITY LED (S62…M2/M3) /

POWER ON LED (S62…M0/M1)