ENTER/EXIT PROGRAMMING MODE
SYMBOLOGIES
84
QUICKSCAN™ I QD2200
GS1 DataBar Expanded Length Control
This feature specifies either variable length decoding or fixed length decoding for the
GS1 DataBar Expanded symbology.
Variable Length:
For variable-length decoding, a minimum length may be set.
Fixed Length:
For fixed-length decoding, two different lengths may be set.
GS1 DataBar Expanded Set Length 1
This feature specifies one of the bar code lengths for "
. Length 1 is the minimum label length if in Variable Length Mode, or
the first fixed length if in Fixed Length Mode. Length includes the bar code’s data charac
-
ters only.
The length can be set from 1 to 74 characters. See "
for more
detailed programming instructions.
$CXBLC00
GS1 DataBar Expanded Length Control
= Variable Length
GS1 DataBar Expanded Length Control = Fixed Length
$CXBLC01
Select GS1 DataBar Expanded Set Length 1 Setting
$CXBL1
To configure this feature, scan the ENTER/EXIT PRO
-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu
-
-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 1 = 01 (one character)