20
READER DEFAULT CONFIGURATION
DATA FORMAT
code identifier disabled (enabled for POS terminals), field adjustment disabled,
code length tx not transmitted, character replacement disabled, address
stamping disabled; address delimiter disabled
POWER SAVE
sleep state/USB suspend disabled, enter sleep timeout = 0.6 sec
READING PARAMETERS
hand-held operation = hardware trigger, stand operation = automatic, trigger
active level, no timeout, Flash On = 1 sec, Flash Off = 0.6 sec, one read per
cycle, safety time 0.5 sec, beeper intensity high, tone 2, beeper type monotone,
beeper length short, good read spot duration medium, automatic operation
aiming light enabled
DECODING PARAMETERS
ink spread enabled, overflow control enabled, interdigit control enabled, Puzzle
Solver™ disabled, decoding safety = one read
CODE SELECTION
Enabled codes
•
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
•
Interleaved 2/5
check digit control and transmission, variable length code; 4-99 characters
•
Standard Code 39
no check digit control, variable length code; 1-99 characters
•
Code 128
variable length code; 1-99 characters
•
EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI,
Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49,
GS1 DataBar™ (GS1 DataBar™ includes the following symbologies:
RSS-14, RSS-14 Stacked, RSS Expanded and RSS Limited).
ADVANCED FORMATTING PARAMETERS
concatenation disabled, no advanced formats defined
RADIO PARAMETERS
radio protocol timeout = 2 seconds, power-off timeout = 4 hours, single store
disabled, beeper control for radio response = normal