background image

DATALOGIC 
 

20   

 

READER DEFAULT CONFIGURATION 

 

DATA FORMAT 

code identifier disabled (enabled for POS terminals), field adjustment disabled, 
code length tx not transmitted, character replacement disabled, address 
stamping disabled; address delimiter disabled 
 

POWER SAVE 

sleep state/USB suspend disabled, enter sleep timeout = 0.6 sec 

 
READING PARAMETERS 

hand-held operation = hardware trigger, stand operation = automatic, trigger 
active level, no timeout, Flash On = 1 sec, Flash Off = 0.6 sec, one read per 
cycle, safety time 0.5 sec, beeper intensity high, tone 2, beeper type monotone, 
beeper length short, good read spot duration medium, automatic operation 
aiming light enabled 
 

DECODING PARAMETERS 

ink spread enabled, overflow control enabled, interdigit control enabled, Puzzle 
Solver™ disabled, decoding safety = one read 
 

CODE SELECTION 

Enabled codes 

 

EAN 8/EAN 13 / UPC A/UPC E without ADD ON 

check digit transmitted, no conversions 

 

Interleaved 2/5 

check digit control and transmission, variable length code; 4-99 characters 

 

Standard Code 39 

no check digit control, variable length code; 1-99 characters 

 

Code 128 

variable length code; 1-99 characters 

 

EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI, 
Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49, 
GS1 DataBar™ (GS1 DataBar™ includes the following symbologies: 
RSS-14, RSS-14 Stacked, RSS Expanded and RSS Limited). 

 

ADVANCED FORMATTING PARAMETERS 

concatenation disabled, no advanced formats defined 
 

RADIO PARAMETERS 

radio protocol timeout = 2 seconds, power-off timeout = 4 hours, single store 
disabled, beeper control for radio response = normal 

Summary of Contents for QuickScan Mobile

Page 1: ...rt POSMicro com Monday Friday 6 AM to 5 PM Pacific Time Bulk Discounts FREE SHIPPING SE Habla Espa ol Free ground shipping to the continental USA on orders over 100 For Help Call 1 800 241 6264 Datalo...

Page 2: ...QuickScanTM Mobile Quick Reference Guide...

Page 3: ...ure that all notices appear on any reproductions of the documentation Should future revisions of this manual be published you can acquire printed versions by contacting your Datalogic representative E...

Page 4: ...9 USB Interface Configuration 10 USB Interface Selection 11 RS 232 Interface Selection 12 Wedge Interface Selection 13 USB Wedge Keyboard Nationality 16 IBM46xx Interface Selection 17 Pen Interface Se...

Page 5: ...s jour de drivers et documentation de ce produit sont disponibles sur Internet Ce manuel est aussi disponible en version fran aise Cliquez sur www scanning datalogic com D Im Internet finden Sie die a...

Page 6: ...s The LEDs signal the QuickScan Mobile cradle status as described in the following table LED BEEPER STATUS Power on Data Yellow On QuickScan Mobile cradle is powered Yellow Blinking the cradle receive...

Page 7: ...cover the entire code Successful scanning is obtained by tilting the reader with respect to the barcode to avoid direct reflections which could impair the reading performance See the figures below Suc...

Page 8: ...before using the reader in hand held mode NOTE In hands free use you can immediately start using the reader since it is powered by the cradle 3 Configure the QuickScan Mobile reader 4 Configure the Q...

Page 9: ...igure 4 Do not incinerate disassemble short terminals or expose to high temperature Risk of fire explosion Use specified charger only Risk of explosion if the battery is replaced by an incorrect type...

Page 10: ...type 1 Connect the appropriate interface cable to the cradle by simply plugging it into the Host connector on the base of the cradle QuickScan Mobile Cradle Bottom View To disconnect the cable insert...

Page 11: ...DATALOGIC 6 IBM USB POS WEDGE ONLY FOR QUICKSCAN M2 TYPE 130 WEDGE ONLY FOR QUICKSCAN M2 TYPE 130 PEN CAB 413 CAB 391 or CAB 321 CAB 431 CAB 431 POWER SUPPLY ADAPTER CAB 431 POWER SUPPLY ADAPTER...

Page 12: ...QUICKSCANTM MOBILE 7 IBM PORT9B IBM PORT 5B ONLY FOR QUICKSCAN M2 TYPE 110 CAB 445 CAB 446...

Page 13: ...ethod you can also send new configuration strings from the PC to the reader or upgrade application software onto the reader QUICKSCAN MOBILE READER CONFIGURATION When the QuickScan Mobile cradle is co...

Page 14: ...le 6 Firmly position the reader onto the cradle within 10 seconds a beep will be emitted signaling that the QuickScan Mobile cradle has been paired to the QuickScan Mobile reader YOUR READER IS NOW RE...

Page 15: ...selected from the dialog box the first time only You can now read codes with the associated QuickScan Mobile reader At this point you can read the USB interface configuration code according to your ap...

Page 16: ...B COM UA02 4 USB IBM Table Top UA00 USB IBM Hand Held UA01 When configuring USB COM the relevant files and drivers must be installed from the USB Device Installation software which can be downloaded f...

Page 17: ...QuickScanTM Mobile cradle restore default code and then read the interface selection code for your application RESTORE QUICKSCAN MOBILE CRADLE DEFAULT RX0 q RS 232 INTERFACE Standard CP0 POS TERMINAL...

Page 18: ...30 Read the QuickScanTM Mobile cradle restore default code then read the interface selection code for your application RESTORE QUICKSCAN MOBILE CRADLE DEFAULT RX0 q WEDGE INTERFACE IBM AT or PS 2 PCs...

Page 19: ...ke only keyboard CP502 o make break keyboard CP501 h KEYBOARD TYPE advanced keyboard FK1 typewriter keyboard FK0 ALT MODE The following interface selection allows barcodes sent to the PC to be interpr...

Page 20: ...MOBILE 15 WEDGE INTERFACE CONTINUED WYSE TERMINALS ANSI Keyboard CP509 9 PC Keyboard CP510 g ASCII Keyboard CP511 n VT220 style Keyboard CP514 DIGITAL TERMINALS VT2xx VT3xx VT4xx CP512 u APPLE APPLE A...

Page 21: ...users should select one of the following KEYBOARD NATIONALITY codes Belge FJ7 8 Deutsch FJ3 English UK FJ4 Espa ol FJ6 3 Fran ais FJ2 Italiano FJ1 Svenskt FJ5 USA FJ0 The following Keyboard Nationalit...

Page 22: ...nTM Mobile cradle restore default code then read the interface selection code for your application RESTORE QUICKSCAN MOBILE CRADLE DEFAULT RX0 q IBM 46XX TERMINALS PORT 9B 4501 Protocol CP800 p typica...

Page 23: ...18 PEN INTERFACE SELECTION Read the QuickScanTM Mobile cradle restore default code then read the interface selection code for your application RESTORE QUICKSCAN MOBILE CRADLE DEFAULT RX0 q PEN INTERF...

Page 24: ...l 1 7 1 6 2 Code 128 t e s t Interleaved 2 of 5 0 1 2 3 4 5 6 7 8 4 YOUR SYSTEM IS READY TO READ CODES AND TO SEND THE DATA TO THE HOST To change the defaults refer to the QuickScanTM Mobile Reference...

Page 25: ...read enabled overflow control enabled interdigit control enabled Puzzle Solver disabled decoding safety one read CODE SELECTION Enabled codes EAN 8 EAN 13 UPC A UPC E without ADD ON check digit transm...

Page 26: ...stamping disabled address delimiter disabled RS 232 Nixdorf DEFAULT SETTINGS 9600 baud odd parity 8 data bits 1 stop bit handshaking hardware RTS CTS ACK NACK disabled FIFO disabled inter character d...

Page 27: ...n to Code 39 overflow medium output level normal idle level normal inter block delay disabled TECHNICAL FEATURES QuickScan Mobile Reader and Cradle Electrical Features READER Battery Type 1 Lithium ba...

Page 28: ...ity 90 non condensing Protection class IP30 Mechanical Features READER Weight without batteries about 189 g 6 66 oz Dimensions 171 x 90 x 68 mm 6 72 x 3 54 x 2 80 in Material Cycoloy C 2800 with desmo...

Page 29: ...B1 1 205 871 B1 and 1 205 873 B1 Additional patents pending SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website Log on to www scanning datalogic c...

Page 30: ...y with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installatio...

Page 31: ...O COMPLIANCE Contact the competent authority responsible for the management of radio frequency devices of your country to verify the eventual necessity of a user license Refer to the web site http eur...

Page 32: ...euillez consulter le site Internet www scanning datalogic com German Informationen zur Entsorgung von Elektro und Elektronik Altger ten WEEE erhalten Sie auf der Webseite www scanning datalogic com Sp...

Page 33: ...IC 28 READING DIAGRAM Reading diagram at 25 C and 300 lux ambient lighting Reading Zones 10 skew angle 0 5 10 15 20 25 30 10 5 0 5 10 cm EAN13 M 1 0 33 mm 13 mils CODE39 0 50 mm 20 mils 0 13 mm 5 mils...

Page 34: ...QUICKSCANTM MOBILE 29 NUMERIC TABLE 01 0 12 1 23 2 34 3 45 4 56 5 67 6 78 7 89 8 9 9...

Page 35: ......

Page 36: ...uf da das Produkt den folgenden Normen entspricht Esta declaraci n se basa en el cumplimiento de los productos con las siguientes normas Datalogic Scanning Inc 07 959 Terry Street Eugene OR 97402 USA...