ELECTRICAL CONNECTIONS
9
4
NOTE:
The AI7000 series illuminators are supplied with a CVL-2389 extension
power cable. Use this cable to connect the PWR-2400 power supply by cutting
off the cable’s male Amphenol connector and connecting the wires to the
PWR-2400 according to the table below:
CVL-2389 Cable to AI7000
Wire Color
Meaning
White
GND (0 V)
Green
+ 24 Vdc
Red
+ 24 Vdc
Black
GND (0 V)
Power distribution is performed simultaneously for the devices. See the device reference
manual for consumption data.