SETUP
28
POWERSCAN™ PD/PM96XX
BC96XX CONFIGURATION
The BC96XX configuration can be performed in three ways: by using the Datalogic Alad
-
din™ software configuration program, by sending configuration strings from the Host PC
via the RS-232 or USB-COM interface or by reading configuration bar codes with the
PowerScan 96XX reader.
Serial Configuration
By connecting the BC96XX to a PC through an RS-232 or USB-COM interface cable it is
possible to send configuration strings from the PC to BC96XX.
Configuration Bar Codes
Link the cradle and the reader using the procedures described in the PowerScan
PM96XX Quick Reference. Once the pairing is complete, you can configure the BC96XX
cradle by reading configuration bar codes in this manual.
To configure the BC96XX using the PowerScan 96XX reader (paired to the cradle with
the Bind command), follow the procedure according to the interface selected.
INTERFACE SELECTION
Upon completing the physical connection between the reader and its host, proceed
directly to the following paragraph "Configuring the Interface" for information and pro
-
gramming for the interface type the reader is connected to (for example: RS-232, Key
-
board Wedge, USB, etc.) and scan the appropriate bar code in that section to select your
system’s correct interfac5e type.
The reader, depending upon the model, will support one of the following sets of host
interfaces:
• USB (Keyboard, COM, OEM)
• USB Composite (Ke COM)
• USB HID POS
• USB Toshiba TEC
• RS-232 STD
• RS-232 WN
• RS232 OPOS
• Keyboard Wedge
• Datalogic Magellan Scanners' specific interface