TECHNICAL SPECIFICATIONS
308
POWERSCAN™ PD/PM96XX
ENVIRONMENTAL CHARACTERISTICS
Operating Temperature
-20° to 50° C (-4° to 122° F)
Recharging Temperature
a
a. NOTE: The higher the ambient temperature, the longer the charging time.
Recommended 0° to 35° C (32° to 95° F)
Max allowed 0° to 40° C (32° to 104° F)
Storage Temperature
-40° to 70° C (-40° to 158° F)
Humidity
0 to 95% non-condensing
Drop Resistance
Withstands 50 drops from 2.5 m/8 ft @20° C;
Withstands 50 drops from 2.0 m/6.6 ft @-20° C
Ambient Light Immunity
100,000 Lux
Contaminants: Spray/rain,
Dust/particulates
IP67 and IP65
ESD Protection
20 KV
ESD: Opening the battery door allows access to electrostatic sensitive
areas. In particular, when connecting and using the microUSB cable, it
is recommended to operate in an environment with low levels of elec
-
trostatic charge (e.g. office) and avoiding the introduction of fingers or
objects into the battery compartment.
RADIO CHARACTERISTICS
Frequency
working center
433MHZ
910MHZ
Programmable Speed
19.2 kb/s
500 kb/s (default)
36.8 kb/s
500 kb/s (default)
Typical Range
(in open air)
100 m (at 500 kb/s)
150 m (at 19.2 kb/s)
180 m (at 500 kb/s)
230 m (at 36.8 kb/s, frequency hopping)
80 m (at 36.8 kb/s, fixed channel)
Max number of devices
per base station
16
NOTE: A radio coverage reduction is expected when the base station is
charging a gun.