background image

Installing the Battery Pack

6

PowerScan™ BT8300

As with other types of batteries, Lithium-Ion (LI) batteries will lose capacity over 
time. Capacity deterioration is noticeable after one year of service whether the 
battery is in use or not. It is difficult to precisely predict the finite life of a LI 
battery, but cell manufacturers rate them at 500 charge cycles. In other words, the 
batteries should be expected to take 500 full discharge / charge cycles before 
needing replacement. This number is higher if partial discharging / recharging is 
adhered to rather than full / deep discharging, 

The typical manufacturer advertised useful life of LI batteries is one to three years, 
depending on usage and number of charges, etc., after which they should be 
removed from service, especially in mission critical applications. Do not continue 
to use a battery that is showing excessive loss of capacity, it should be properly 
recycled / disposed of and replaced. For most applications, batteries should be 
replaced after one year of service to maintain customer satisfaction and minimize 
safety concerns.

Collect and recycle waste batteries separately from the device in comply with 
European Directive 2006/66/EC, 2002/95/EC, 2002/96/EC and subsequent 
modifications, US and China regulatory and others laws and regulations about the 
environment. 

CAUTION

Always charge the battery at 32° – 113°F (0° - 45°C) tempera-
ture range.

Use only the authorized power supplies, battery pack, char-
gers, and docks supplied by your Datalogic reseller. The use of
any other power supplies can damage the device and void your
warranty. 

Do not disassemble or modify the battery. The battery contains
safety and protection devices, which, if damaged, may cause
the battery to generate heat, explode or ignite.

Do not place the battery in or near fire, on stoves or other high
temperature locations.

Do not place the battery in direct sunlight, or use or store the
battery inside cars in hot weather. Doing so may cause the bat-
tery to generate heat, explode or ignite. Using the battery in
this  manner  may  also  result  in  a  loss  of  performance  and  a
shortened life expectancy.

Do not place the battery in microwave ovens, high-pressure
containers or on induction cookware.

Immediately discontinue use of the battery if, while using,
charging or storing the battery, the battery emits an unusual
smell, feels hot, changes color or shape, or appears abnormal
in any other way.

Do not replace the battery pack when the device is turned on. 

Do not remove or damage the battery pack’s label. 

Do not use the battery pack if it is damaged in any part. 

Battery pack usage by children should be supervised. 

Summary of Contents for PowerScan BT8300 Family

Page 1: ...PowerScan BT8300 Family Industrial Handheld Bar Code Reader with Bluetooth Wireless Technology Quick Reference Guide...

Page 2: ...anning datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic publica tions please let us know via the Con...

Page 3: ...king the PowerScan BT8300 to the BC 8030 BT Cradle 10 Link by Contact 11 Link by Inquiry 12 Link by Label 12 Linking the PowerScan BT8300 to a Bluetooth Enabled PC 13 Linking to a PC in Serial Port Pr...

Page 4: ...2 PowerScan BT8300 Laser Safety Compliance 24 LED CLASS 25 IC Industry Canada 25 WEEE Compliance 26 Hex Numeric Table 27...

Page 5: ...oded data PowerScan BT8300 laser readers automatically scan bar codes at a distance Simply aim and pull the trigger Scan Line Position Code scanning is performed along the scan line emitted from the r...

Page 6: ...ot which should be aimed over the code center to get the best reading performance see 1 in the figure above By completely pressing the trigger the scan line appears to start the code scanning see 2 Af...

Page 7: ...Lithium ion battery packs may get hot explode or ignite and causeseriousinjuryifexposedto abusiveconditions Besureto follow the safety warnings listed below Do not place the battery pack in fire or he...

Page 8: ...C and subsequent modifications US and China regulatory and others laws and regulations about the environment CAUTION Always charge the battery at 32 113 F 0 45 C tempera ture range Use only the author...

Page 9: ...r LED on the cradle battery charger turns red The battery is completely charged when the Reader LED on the cradle battery charger turns green Figure 1 Changing the Batteries Do not incinerate disassem...

Page 10: ...that the default mode on PowerScan BT8300 is Handheld Cradle communication Restore PowerScan BT 8300 Default Date and Time Setup Scan the following bar codes in sequence to set the date and time for...

Page 11: ...3 Configure the reader as described in this Quick Reference Linking the PowerScan BT8300 to the BC 8030 BT Cradle on page 10 4 Configure the BC 8030 BT cradle See BC 8030 BT Configuration in the BC 8...

Page 12: ...erScan BT8300 reader from a Bluetooth Enabled PC to make it available for pairing with another PC Read the bar code above to disconnect the reader from its PC Please note that in order to connect diff...

Page 13: ...nd the yellow LED on the cradle will stop blinking 6 To connect another PowerScan PBT8300 to the BC 8030 BT cradle repeat the sequence from steps 1 through 5 One Cradle can connect with a maximum of f...

Page 14: ...e cradle press the trigger on the reader within 10 seconds before the timeout expires 7 Four ascending beeps will be emitted signaling that the BC 8030 BT cra dle has been successfully connected to th...

Page 15: ...assigned to your scanner A window will notify you of Incoming Port and Outcoming Port when the PowerScan BT8300 is successful added to the PC 5 Open the Outcoming Port using your application program...

Page 16: ...2 Open the Incoming Port using your application program for test purposes you can verify the communication using the Hyperterminal tool in Win dows 6 When prompted for a passkey enter the default of 1...

Page 17: ...on the Host such as WIDCOMM and BlueSoleil 8 require a Variable PIN Code When attempting connection the application presents a window that includes a PIN Code which is to be input using the PowerScan...

Page 18: ...300 16 PowerScan BT8300 PowerScan BT8300 HID Configuration HID Country Codes Country Code U S Country Code Italy Country Code France Country Code Germany Country Code Britain Country Code Sweden Count...

Page 19: ...Quick Reference Guide 17 HID Country Codes cont Country Code Belgium Country Code Japanese 106 key Country Code Poland Country Code Hungary Country Code Croatia Country Code Romania Country Code Czech...

Page 20: ...Connecting the PowerScan BT8300 18 PowerScan BT8300 HID Country Codes cont Country Code Denmark Country Code Norway Country Code Portugal Country Code Switzerland...

Page 21: ...19 Caps Lock State This option specifies the format in which the reader sends character data Caps Lock Auto Recognition IBM AT Compatible Only Alt Mode Caps Lock State Caps Lock OFF Caps Lock State Ca...

Page 22: ...Code 93 Codabar pharmaceutical codes MSI Code 11 Code 16K Code 49 GS1 DataBar GS1 DataBar includes the following symbologies GS1 DataBar Omnidirectional GS1 DataBar Stacked GS1 DataBar Expanded and G...

Page 23: ...76 mm 3 mils 0 19 mm 7 5 mils PCS minimum Datalogic Test Chart 15 25 Scan Angle 42 13 5 0 7 Laser Safety Class 2 EN 60825 1 CDRH Bluetooth Features Protocol Bluetooth 2 0 Class 1 or Class 2 configurab...

Page 24: ...3 5 24 2 cm 1 4 9 5 in 10 2 9 42 8 cm 1 1 16 8 in 13 2 3 55 1 cm 0 9 21 7 in 20 6 3 78 5 cm 2 5 30 9 in 40 2 5 97 8 cm 1 0 38 5 in mil Typical reading distance with good quality codes 7 5 18 50 cm 7 0...

Page 25: ...ng datalogic com and click on the links indicated for further information including PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Softwar...

Page 26: ...s device must accept any interference received including interference which may cause undesired operation FCC ID U4F0015 Radio Compliance Contact the competent authority responsible for the management...

Page 27: ...C Industry Canada Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause und...

Page 28: ...logic com German Informationen zur Entsorgung von Elektro und Elektronik Altger ten WEEE erhalten Sie auf der Webseite www scanning datalogic com Spanish Si desea informaci n acerca de los procedimien...

Page 29: ...Hex Numeric Table Quick Reference Guide 27 Hex Numeric Table 01 0 12 1 23 2 34 3 45 4 56 5 67 6 78 7 89 8 9 9...

Page 30: ...Hex Numeric Table 28 PowerScan BT8300 Hex Numeric Table continued A B C D E F Cancels an incomplete configuration sequence Exit and Save Configuration...

Page 31: ...ukt den folgenden Normen entspricht Esta declaraci n se basa en el cumplimiento delos productos con las siguientes normas Datalogic Scanning Inc 07 959 Terry Street Eugene OR 97402 e tutti i suoi mode...

Page 32: ...Telephone 39 0 39 62903 1 italy scanning datalogic com Japan Datalogic Scanning KK Telephone 81 0 3 3491 6761 japan scanning datalogic com Latin America Datalogic Scanning Inc Telephone 305 591 3222 l...

Reviews: