MATRIX 450™ REFERENCE MANUAL
54
4
NOTE
For applications that do not use RX485 signals, do not leave these lines
floating but connect them to SGND as shown below.
RX485+
SGND RX485-
USER INTERFACE
SGND TX+
TX-
READER
Figure 32 - RS485 Full-duplex Connections using Only TX Signals
4.2.3 RS485
Half-Duplex
Interface
NOTE
This interface is provided for backward compatibility. We recommend using
the more efficient ID-NET™ network for Master/Slave or Multiplexer layouts.
The RS485 half-duplex (3 wires + shield) interface is used for polled communication
protocols.
It can be used for Multidrop connections with a Datalogic Multiplexer, exploiting a proprietary
protocol based on polled mode called MUX32 protocol, where a master device polls slave
devices to collect data.
CBX100/500
Function
RTX+
RS485 Receive/Transmit Data +
RTX-
RS485 Receive/Transmit Data -
SGND Signal
Ground
SGND RTX485-
USER INTERFACE
SGND RTX+
RTX-
READER
Figure 33 - RS485 Half-duplex Connections