MATRIX 210™ PARAMETERS LIST
25
4
4.2 CALIBRATION
PARAMETER TYPE
SEL
STRING
DATA
IMAGE ACQUISITION SETTING (DEPTH: n = 1 to 10)
Status
#n
1
1
ESC a
#n
0 = Disabled
1 = Enabled
Self Tuning
#n
1
1
ESC
G
#n
0 = Disabled
1 = Enabled
Self Tuning Mode
#n
1
1 ESC
H
#n
0 = Gain Only
1 = Exposure Time Only
2 = Exposure Time And Gain
Self Tuning Timeout
(ms)
#n
0 0
ESC
I
#n
Range: 1 to 10000
(0 = Disabled)
Internal Lighting Mode
#n
1 1
ESC
j
#n
0 = Disabled
1 = Always On
2 = Very High-Power Strobed
3 = High-Power Strobed
4 = Medium-Power Strobed
Exposure Time
#n
Very High-Power
Strobed (x 10
s)
0 ESC
b
#n
Range: 1 to 60
Exposure Time
#n
High-Power Strobed (x
100
s)
0 ESC
c
#n
Range: 1 to 50
Exposure Time
#n
Medium-Power Strobed
(x 1 ms)
0 ESC
d
#n
Range: 1 to 26
Exposure Time
#n
Disabled, Always On (x
10
s)
0 ESC
e
#n
Range: 1 to 2600
Gain
#n
0
ESC
f
#n
Range: 1 to 40
Gain Increasing
#n
1
1 ESC
h
#n
0 = x1
1 = x2
2 = x3
3 = x4
4 = x5
5 = x6
6 = x7
7 = x8
8 = x9
9 = x10
Image Polarity Inversion
#n
1 1
ESC
i
#n
0 = Disabled
1 = Enabled
Region Of Interest:: Top
#n
0 ESC
A
#n
Range: 0 to 479
Region Of Interest::
Bottom
#n
0 ESC
B
#n
Range: 0 to 479
Region Of Interest:: Left
#n
0 ESC
C
#n
Range: 0 to 751
Region Of Interest:
Right
#n
0 ESC
D
#n
Range: 0 to 751
NOTE
Special characters <
FE
H
> and <
FD
H
> must be added after
#n
in the
programming string to indicate parameter
Depth > 9
. Refer to paragraph 3.2
for further details.
Summary of Contents for Matrix 210
Page 1: ...MATRIX 210 Host Mode Programming...
Page 4: ...iv...
Page 80: ...www automation datalogic com...