PROGRAMMING STRINGS
11
3
If sequence contents are wrong (i.e. a typing error in the file) or due to a transmission error,
the device replies with the following message:
<ESC> W 1 <CR><LF>
After transmitting the proper reply message, the device then waits for one or more get strings
or one or more programming strings or the exit from host mode command.
3.4 DATA STORAGE COMMANDS
The Matrix device data storage programming command must have the following format:
<ESC> I A MODE
Where:
MODE
:
Data storage mode. The possible values are:
!
= Storage in temporary (volatile) memory only.
Space
= Storage in temporary and permanent memory.
This command must always be transmitted to exit from programming mode.
If the programming is correct, the device updates the configuration and confirms with the
following message:
<ESC> K <CR><LF>
If programming contents are wrong (i.e. a typing error in the file) or due to a transmission
error, the device replies with the following message and programming data will not be
updated in this case:
<ESC> W 1 <CR><LF>
After transmitting the proper reply message, the device then waits for new programming
session or exit from host mode.