Scanning Features
Product Reference Guide
243
Flash On Time
This feature specifies the ON time for the indicator LED while in Flash Mode.
The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100
millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the
result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05,
20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode.
4. Scan the bar code: SELECT FLASH ON TIME SETTING on
page 83
5. Scan the appropriate two digits from the keypad in
Appendix D, Keypad
rep-
resenting the duration which was determined in the steps above. You will
hear a two-beep indication after the last character.
NOTE
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mode.
This completes the procedure. See the table below for examples of how to set
this feature.
Table 19. Flash On Time Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
500ms
1,000ms (1 sec.) 5200ms (5.2 sec.)
9,900ms (9.9 sec.)
2
Divide by 100 (and pad with
leading zeroes to yield two
digits)
05
10
52
99
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT FLASH ON TIME SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘5’
‘1’ and ‘0’
‘5’ and ‘2’
‘9’ and ‘9’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for Heron HD3130
Page 1: ...Heron HD3130 Linear Imager Product Reference Guide...
Page 10: ...viii Heron HD3130 NOTES...
Page 14: ...Introduction 4 Heron HD3130 NOTES...
Page 56: ...Keyboard Interface 46 Heron HD3130 NOTES...
Page 226: ...Enter Exit Programming Mode BC412 216 Heron HD3130 NOTES...
Page 258: ...References 248 Heron HD3130 NOTES...
Page 265: ...Stand Dimensions Product Reference Guide 255 Stand Dimensions...
Page 266: ...Technical Specifications 256 Heron HD3130 Stand Base Plate Template SCREW HERE SCREW HERE...
Page 284: ...Sample Bar Codes 274 Heron HD3130 NOTES...
Page 286: ...Keypad 276 Heron HD3130 Keypad continued 5 6 7 8 9 A B...
Page 287: ...Product Reference Guide 277 Keypad continued C D E F...
Page 288: ...Keypad 278 Heron HD3130 NOTES...