Reading Parameters
Product Reference Guide
237
Reading Parameters
Label Gone Timeout
This feature sets the time after the last label segment is seen before the scan-
ner prepares for a new label. The timeout can be set within a range of 10 milli-
seconds to 2,550 milliseconds (2.55 seconds) in 10ms increments. Label Gone
Timeout does not apply to scan modes that require a trigger pull for each label
that is read
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the
result with leading zeroes to yield three digits. For example: 0 = 000, 5 =
005, 20 = 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode.
4. Scan the bar code: SELECT LABEL GONE TIMEOUT SETTING on
page 83
.
5. Scan the appropriate three alpha-numeric characters from the keypad in
Appendix D, Keypad
representing the duration which was determined in the
steps above. You will hear a two-beep indication after the last character.
NOTE
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mode.
This completes the procedure. See the table below for examples of how to set
this feature.
Table 14. Label Gone Timeout Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
50ms
150ms
1800ms (1.8 sec.)
2550ms (2.55 sec.)
2
Divide by 10 (and pad with
leading zeroes)
005
015
180
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT LABEL GONE TIMEOUT SETTING
5
Scan Three Characters From
Appendix D, Keypad
‘0’, ‘0’ and ‘5’
‘0’, ‘1’ and ‘5’
‘1’, ‘8’ and ‘0’
‘‘2’, ‘5’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for Heron HD3130
Page 1: ...Heron HD3130 Linear Imager Product Reference Guide...
Page 10: ...viii Heron HD3130 NOTES...
Page 14: ...Introduction 4 Heron HD3130 NOTES...
Page 56: ...Keyboard Interface 46 Heron HD3130 NOTES...
Page 226: ...Enter Exit Programming Mode BC412 216 Heron HD3130 NOTES...
Page 258: ...References 248 Heron HD3130 NOTES...
Page 265: ...Stand Dimensions Product Reference Guide 255 Stand Dimensions...
Page 266: ...Technical Specifications 256 Heron HD3130 Stand Base Plate Template SCREW HERE SCREW HERE...
Page 284: ...Sample Bar Codes 274 Heron HD3130 NOTES...
Page 286: ...Keypad 276 Heron HD3130 Keypad continued 5 6 7 8 9 A B...
Page 287: ...Product Reference Guide 277 Keypad continued C D E F...
Page 288: ...Keypad 278 Heron HD3130 NOTES...