GWY-01-PBS-01
28
4
Command ID Command Name
Description
0x1C
Get Subnet Baud Rate
Retrieves the baud rate of the Subnet
network
0x21
Set Gateway Name
Writes to flash memory, a user-defined
“friendly” name for the Gateway
0x24
Set Notification Mask
Used to customize or modify the
Gateway’s 16-bit Notification Mask
0x26
Set Gateway Time
Used to set the Gateway’s internal clock
and calendar
0x2C
Set Subnet Baud Rate
Used to modify and store changes to the
Subnet network baud rate
RFID Controller Commands
0x30
Get Controller Name
Retrieves the controller’s user-defined
name
0x33
Get Controller Configuration
Retrieves the controller’s configuration
settings
0x38
Get Controller Info
Retrieves hardware, firmware and serial
number information from the controller
0x40
Set Controller Name
Used to set (create or modify) the user-
defined name for the controller
0x43
Set Controller Configuration
Used to set (configure or modify) the
controller’s configuration parameters and
settings
0x4E
Set Controller Time
Used to set the time for the controller
0x53
Initialize Controller
Removes all configuration settings stored
for the controller
0x54
Reset Controller
Resets power to the controller
Gateway Subnet Commands
0x60
Initialize Gateway
Clears all Subnet Node configuration
information stored in the Gateway’s flash
memory
0x61
Reset Gateway
Performs an electrical reset of the
Gateway
0x62
Initialize All Nodes
Removes all stored configuration
information for all nodes and reconfigures
them to factory defaults
0x63
Initialize All Node Macros
Removes all stored macros from all
nodes
0x70
Start Subnet
Instructs the Gateway to begin “polling”
the Subnet network
0x71
Move Controller
Used to move all stored configuration
data for a particular Node ID to another
specified Node ID