GWY-01-PBS-01
16
2
2.3.3 Subnet16™
RS485
The Gateway Subnet16™ RS485 Connector (M12 5PF) is used for connecting to the
Subnet16 network and RFID controllers.
Figure 16: M12 5PF Subnet16™ RS485 Interface Connector
Pin
Name
Function
1
Shield Cable
shield
2
Vdc
Power supply input v
3
GND
Power supply input voltage -
4
RTX+
RS485 Receive/Transmit Data +
5
RTX-
RS485 Receive/Transmit Data -
2.4 POWER & WIRING
The information presented below is provided to assist the installer in determining the amount
of power that will be required by the Gateway and its Subnet network.
2.4.1 Power
Requirements
The Gateway requires an electrical supply voltage of 12 to 30 Vdc. In addition, each RFID
controller connected to the Gateway via the Subnet16™ network will also require power. Use
a regulated power supply that is capable of delivering the requirements listed in the
Technical Features.
NOTE
Power is applied directly to the Subnet16™ Network trunk and distributed
through drop cables to the Gateway and RFID controllers. By positioning the
power supply near the middle of the network, you can limit voltage drop at
the ends, (see Appendix B for network layout diagrams).
The following information is provided to assist you in determining the power requirements of
your RFID application.