CODE SELECTION 

issue identical codes = enable 

enabled codes

Standard Code 39: no check digit control, variable code length; 
EAN 8/EAN 13 / UPC A/UPC E without ADD ON: UPCE expansion disabled 
Interleaved 2/5: check digit control and transmission, variable code length 
Code 128: variable code length 
PDF417
Datamatrix: rectangular, normal and inverted, variable code length 
QR

disabled codes

Code 32, Codabar, Code 93, EAN 128, RSS, Micro PDF417, Postal Codes, 
Maxicode, Composite Codes. 

READING PARAMETERS 

trigger type normal, trigger level mode, flash on = 2 sec, flash off = 2 sec, 
beeper tone = tone 1, beeper volume = high, beeper duration = 50 ms, user 
defined beeper = tone 1, user defined beeper volume = high, user defined 
beeper duration = 100 ms, code per scan = one code per scan, read per 
cycle = one read per cycle, scan timeout = 5 sec, central code transmission 
enabled, order by code length disabled, order by code symbology disabled, 
autoscan mode disabled, autoscan aiming system enabled, autoscan 
hardware trigger enabled, autoscan illumination system disabled, stand 
autoscan mode = normal, aiming system delay = disabled, good read spot = 
disabled 

IMAGE FORMATTING 

Image Preset 1, 2, 3, 4 

image format = JPEG, resolution = full (640 x 480), set JPEG quality 
factor = 50, window origin = (0, 0), window dimensions = (640 x 480), 
brightness = 0%, contrast = 0%, zoom = 100%, color depth = 256 gray level. 

 
 

13 

 

Summary of Contents for Gryphon D432

Page 1: ...Gryphon D432 D432E Quick Reference...

Page 2: ......

Page 3: ...Gryphon D432 D432E QUICK REFERENCE...

Page 4: ...ents without prior notification Datalogic shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the use of this...

Page 5: ...rs 4 Setup 4 Connections 5 Disconnecting the Cable 6 USB Interface Configuration 6 Interface Selection 8 Wedge Keyboard Nationality 9 USB Keyboard Nationality 10 Reading Parameters 11 Default Configur...

Page 6: ...ses jour de drivers et documentation de ce produit sont disponibles sur Internet Ce manuel est aussi disponible en version fran aise Cliquez sur www datalogic com D Im Internet finden Sie die aktuells...

Page 7: ...tream acquired from decoding a symbol is rapidly sent to the host The reader is immediately available to read another symbol Formatting and Concatenating The string of a decoded code may be processed...

Page 8: ...iming system you will get a good read The field of view changes size as you move the reader closer or farther away from the code Linear barcode 2D Matrix symbol Relative Size and Location of Aiming Sy...

Page 9: ...in reading distance will occur due to narrow bar width and other factors NOTE If reading codes positioned on reflective surfaces it may be necessary to tilt the reader with respect to the barcode and...

Page 10: ...Its tone volume and duration can be directly configured by using the codes given in the Gryphon D432 D432E Reference Manual available on the website The application program can also manage the beeper...

Page 11: ...GRYPHON D432 D432E CONNECTIONS RS232 WEDGE USB The Gryphon D432 D432E reader requires the USB interface cable CAB412 If required 5...

Page 12: ...e is included in the Host Operating System and will either be loaded automatically or will be suggested by the O S and should therefore be selected from the dialog box the first time only If the Host...

Page 13: ...en LED blinks Green LED off BEEP OK BEEP OK Connect Gryphon D432 D432E to Host Disconnect reader at Host Connect external power supply to cable and power up Reconnect reader cable to Host and close di...

Page 14: ...DLLLLDDDLDDLDLLL AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAMDKEOFMHMLJAKEDBEKK AMGNPJCJGIIJCMCFHMNJLBJPHK AIFBJLBGMHPKNMBGMJOJEHHAOK AAPHBAJICDHCJBCNKPCNNJNFHK AFLFBMPJIKPAMFFBBHKCCKNIKK DLLDLDLDLLDLLLLDDDDDD...

Page 15: ...DK AIFBJLBGMHPKMLCDNHNJKCLBOK AAPHBAJJCGAPNGHEMNNHNFKPHK AFKFBKNBNCFAGLFNAHKMIMBLKK DLLDLDLDDLDLLLLDLDDDDLDLLL Italian Japanese AMHKHNFMFNGNENEIEPANHOGOCK AGPEPBIMDKEOFMHMLJALEFGEKK AEONPJCJGIIJCMCFGL...

Page 16: ...BJLBGMHPKNMDEHIKOLINBOK AAPHBAJICGDJGPKAKCKBEKMLHK AHLFBIMDDIPAOJGJGFJGCLLJJK DLLDLDLDLDDLLLLDDLLDDLDLLL Italian Japanese AMHKHNEIHNGNENEIEPANHOGOCK AGPEPBIMDKEOFMHMLJALFEAFKK AEONPJCJGIIJCMCEGPNHDEMN...

Page 17: ...LDLDLDLLLLLLLDDDDDDLDLLL Medium Long AMHKHNGMFNGNENEIEPANHOGOCK AHOEHJAMDKEOFMHMLJAKEGHHJK AMONPJCJGIIJCMCEGINEKCFHPK AIFBJLBGMHPKNOCIIAKMBLLBOK AAPHBAJIDGDNBPGKECMDIHBFHK AGLFBIKBBEFKCJDNNKIOCCHIIK D...

Page 18: ...header terminator CR LF Wedge no header terminator ENTER USB Keyboard no header terminator ENTER DATA FORMAT Symbology Dependent Parameters custom code identifier disabled symbology specific format se...

Page 19: ...sec beeper tone tone 1 beeper volume high beeper duration 50 ms user defined beeper tone 1 user defined beeper volume high user defined beeper duration 100 ms code per scan one code per scan read per...

Page 20: ...DATALOGIC OPERATING TEST EAN 13 Code 39 Standard 1 234567 000992 1 7 1 6 2 Code 128 PDF417 t e s t QR Data Matrix Normal 14...

Page 21: ...m 7 04 x 3 18 x 3 85 inches Weight 198 g 6 9 oz without cable Decoding Capability 1D Interleaved 2 of 5 Code 39 Code 32 Code 128 EAN 128 Code93 UPC EAN JAN Codabar RSS 2D PDF417 Micro PDF417 Macro PDF...

Page 22: ...imension mm mils Symbol size cm in DOF cm in POSTNET 0 5 20 4 0 x 0 4 1 57 x 0 16 11 5 to 30 0 4 52 to 11 81 PDF417 0 13 5 1 1 x 0 9 0 43 x 0 35 8 0 to 14 0 3 14 to 5 51 0 17 6 6 1 4 x 1 2 0 55 x 0 47...

Page 23: ...076 3 1 2 x 4 0 0 47 x 1 57 4 9 to 7 2 1 92 to 2 83 0 13 5 1 2 x 4 0 0 47 x 1 57 4 0 to 8 7 1 57 to 3 42 2D X dimension mm mils Symbol size cm in DOF cm in PDF417 0 76 3 0 65 x 0 55 0 26 x 0 22 4 5 t...

Page 24: ...ns and Maintenance Agreements Authorised Repair Centres CONTACT US E mail form and listing of Datalogic Subsidiaries WARRANTY Datalogic warranties this product against defects in workmanship and mater...

Page 25: ...ndesired operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable...

Page 26: ...arding its Aiming System LED Illuminator The use of an illuminator in the Gryphon D432 D432E hand held reader is a Class 1 LED product ILLUMINATORE LED CLASSE 1 AUSLEUCHTER LED KLASSE 1 ILLUMINATEUR A...

Page 27: ...0825 1 2001 RAYO L SER NO MIRAR FIJO EL RAYO APARATO L SER DE CLASE 2 M XIMA POTENCIA DE SALIDA LONGITUD DE ONDA EMITIDA CONFORME A EN 60825 1 2001 ENGLISH The following information is provided to com...

Page 28: ...tre di dirigere il raggio laser negli occhi di un osservatore anche attraverso superfici riflettenti come gli specchi DEUTSCH Die folgenden Informationen stimmen mit den Sicherheitshinweisen berein di...

Page 29: ...vers des surfaces r fl chissantes miroirs par exemple ESPA OL Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso...

Page 30: ...anty POWER SUPPLY This device is intended to be connected to a UL Listed CSA Certified computer which supplies power directly to the reader or else be supplied by a UL Listed CSA Certified Power Unit...

Page 31: ...ectromagnetic compatibility and product safety Bas e sur la l gislation des Etats membres relative la compatibilit lectromagn tique et la s curit des produits ber die Ann herung der Gesetze der Mitgli...

Reviews: