ENTER/EXIT PROGRAMMING MODE
176
Gryphon™ I GD4132/GM4102/GBT4102
I 2 of 5 Set Length 1
This feature specifies one of the barcode lengths for
.
Length 1 is the minimum label length if in
Mode, or the first
fixed length if in
Mode. The length includes the barcode’s check
and data characters. The length can be set from 2 to 50 characters in incre-
ments of two.
provides some examples for setting Length 1. See
detailed instructions on setting this feature.
Table 8. I 2 of 5 Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
2 Characters
6 Characters
14 Characters
50 Characters
2
Pad with leading zeroes to
yield two digits
02
06
14
50
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT I 2 of 5 LENGTH 1 SETTING
5
Scan Two Characters From
‘0’ and ‘2’
‘0’ and ‘6’
‘1’ and ‘4’
‘5’ AND ‘0’
6
Scan ENTER/EXIT PROGRAMMING MODE
Select I 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort
and not save the entry string. You can then start again
at the beginning.
CANCEL
DEFAULT
06 = Length 1 is 6 Characters
Summary of Contents for Gryphon BT4102
Page 18: ...Introduction 16 Gryphon I GD4132 GM4102 GBT4102 NOTES ...
Page 40: ...Setup 38 Gryphon I GD4132 GM4102 GBT 4102 NOTES ...
Page 44: ...Configuration Using Barcodes 42 Gryphon I GD4132 GM4102 GBT 4102 NOTES ...
Page 260: ...ENTER EXIT PROGRAMMING MODE 258 Gryphon I GD4132 GM4102 GBT4102 NOTES ...
Page 324: ...Technical Specifications 322 Gryphon I GD4132 GM4102 GBT4102 NOTES ...
Page 341: ...Product Reference Guide 339 A B C D E F ...
Page 342: ...Keypad 340 Gryphon I GD4132 GM4102 GBT4102 NOTES ...
Page 352: ...Scancode Tables 350 Gryphon I GD4132 GM4102 GBT4102 NOTES ...