background image

DX8200A-3002 QUICK GUIDE 

10 

 

 

 

Once the scanner is correctly positioned for PackTrack, fix the stops against the scanner. The stops remain 
fixed to the station frame so that the scanner can be replaced without having to recalibrate the PackTrack 
coordinates. Referring to the figure above, the stop provides a reference point for the X-axis while the scanner 
should be centered on the frame to have a fixed reference for the Y-axis. 

 
 
 

SCANNER DIRECTION 

 
The different scanner orientations are illustrated in the following figures: 
 

 

 

DX8200A-3002 Scanner Direction 0° (Forward) 

DX8200A-3002 Scanner Direction 180° (Reverse) 

 
 
 

READING DIAGRAMS 

 

Note:

  x = 0 and z = 0 correspond to the edge of the DX8200A-3002 scanner as shown in the figure below.

 

 

DX8200A-3002 (0.50 mm/20 mils)

 

 

 
 

CONDITIONS 

Code = Interleaved 2/5 or Code 39 
PCS = 0.90

 

0

-24

-40

(in)

-32

-48

0

-60

-80

(cm)

-100

-120

-140 

-160 

-56 

-64 

(in)

-30

-20

0

-10

(cm)

-50

-60

-70

-40

30

20

10

50

60

70

40

-12

-8

0

-4

-20

-24

-28

-16

12

8

4

20

24

28

16

-40

-15

 

 

x

Top View 

Conveyor Direction 

Top View 

Conveyor Direction

Summary of Contents for DX8200A-3002

Page 1: ...DX8200A 3002 QUICK REFERENCE GUIDE 821001253 Rev C...

Page 2: ...atalogic com and click on the links indicated for further information PRODUCTS Search through the links to arrive at your product page which describes specific Info Features Applications Models Access...

Page 3: ...eypad 1 Phase On LED Yellow 3 Power On LED Green 2 TX Data LED Green 5 Network LED Red 6 Encoder LED Yellow 4 LCD Display 7 Figure C Lonworks 17 pin Male Connector 1 Lonworks 17 pin Female Connector 2...

Page 4: ...000 A H G C D B E F PWO Extended I O Host HUB ETHERNET SC6000 AUX CAB SC6003 CAB SC6013 Power Net VAC INPUT CAB SC6103 Cable PWO LONWORKS ENCODER PS PS Aux CAB 85xx CAB 85xx CAB 85xx CAB 85xx CAB 85xx...

Page 5: ...PS PS Aux CAB 85xx CAB 85xx BTK 8500 CAB 85xx CAB 85xx CAB 85xx Extended I O ETHERNET SC6000 CAB SC6003 CAB SC6013 Power Net VAC INPUT PWO CAB PWO 03 Redundancy CAB 85xx CAB 85xx CAB 85xx BTK 8500 DX8...

Page 6: ...ield B internally connected by 3 CHASSIS capacitor to chassis 4 TXAUX Transmit data of auxiliary RS232 referred to SGND 5 SGND Signal ground connected to GND 6 RXAUX Receive data of auxiliary RS232 re...

Page 7: ...of motor slow down READING FEATURES Scan Rate 1000 scans s 500 per leg Maximum Resolution Max Reading Distance Max Reading Width Max Depth of Field see reading diagrams on page 10 USER INTERFACE LCD...

Page 8: ...ion Part Number Power Supply PWO 480 Power and Connect System 480W 93ACC1767 Cables and Terminators BTK 8100 Bus Terminator Kit 5 pcs 93ACC1090 BTK 8500 IP65 Terminator Kit 2 pcs 93A051286 CAB 8100 10...

Page 9: ...occur that the laser of the blinded scanner starts blinking due to an internal circuit which temporarily turns the laser off when detecting a power anomaly To resolve this problem it is sufficient to...

Page 10: ...ference for the Y axis SCANNER DIRECTION The different scanner orientations are illustrated in the following figures DX8200A 3002 Scanner Direction 0 Forward DX8200A 3002 Scanner Direction 180 Reverse...

Page 11: ...ware command see also the Genius Help On Line LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAXIMUM OUTPUT RADIATION 1 mW EMITTED WAVELENGTH 630 680 nm TO EN 60825 1 2001 CAUTION CLASS 3B L...

Page 12: ...likely to cause harmful interference in which case the user will be required to correct the interference at his own expense POWER SUPPLY This product is intended to be installed by Qualified Personnel...