DSM0400 Fixed Mount Area Imager Bar Code Reader
34
DSM0400
Common Cleaning Solutions
The cleaners and disinfectants listed below are tested for use on
device enclosure:
•
Chlorine Bleach (diluted 10:1)
•
Hydrogen Peroxide 3%
•
Isopropyl Alcohol 70%
•
Formula 409® Multi-Surface Cleaner
•
Windex® Multi-Surface Cleaner / Vinegar
Cleaning enclosure and window surfaces
1. Moisten a soft cloth with a recommended cleaning solution. Be
sure to apply the solution to your cloth first. Wring excessive liq-
uid from the cloth.
2. Use the cloth to wipe down the surface of the unit. Use cotton
swabs, lightly moistened, to reach in corners and crevices.
3. Use another clean dry cloth to remove any residue of the cleaning
agent and ensure the unit is dry.
Disinfectants may be harsh on metal. They are recommended for
use only on enclosures.
CAUTION
DO NOT spray or pour cleaner directly onto the unit.
DO NOT use solutions in their concentrated form.
DO NOT use aerosols, solvents or abrasives.
DO NOT use paper towels or rough cloths to clean windows.