
INSTALLATION
3
RS232 Interface
The serial interface is used in this case for point-to-point connections; it handles
communication with the host computer and allows both transmission of code data
and the programming of the scanner. This is the default setting.
The following pins are used for RS232 interface connection:
Pin Name
Function
2 TX232
transmit
data
3 RX232
receive
data
4
RTS232
request to send
5
CTS232
clear to send
7 SGND
signal
ground
It is always advisable to use shielded cables. The overall maximum cable length
must be less than 15 m (49.2 ft).
DS2400N
7
4
5
3
SGND
RTS232
CTS232
RX232
TX232
2
USER INTERFACE
SGND
DCD
DTR
TXD
RXD
1
Chassis
Figure 18 – RS232 Main Interface Connections using Hardware Handshaking
The RTS232 and CTS232 signals control data transmission and synchronize the
connected devices.
33
Summary of Contents for DS2400N
Page 1: ...DS2400N REFERENCE MANUAL ...
Page 5: ...GLOSSARY 70 INDEX 74 v ...
Page 10: ...x ...
Page 20: ...DS2400N 1 b Operating mode selection and definition c Digital Outputs configuration 10 ...
Page 49: ...INSTALLATION 3 Figure 23 ID NET Network Connections with isolated power blocks 39 ...
Page 50: ...DS2400N 3 Figure 24 ID NET Network Connections with Common Power Branch Network 40 ...
Page 51: ...INSTALLATION 3 Figure 25 ID NET Network Connections with Common Power Star Network 41 ...