
INTRODUCTION
2
The protection class of the enclosure is IP65, the reader is therefore suitable for
industrial environments where high protection against harsh external conditions is
required.
2.1.1 Indicators
The five LEDs on the side of the scanner indicate the following:
READY
(green)
This LED indicates the device is ready to operate.
(Figure A, 8)
GOOD
(green)
This LED confirms successful reading. (Figure A, 7)
TRIGGER
(yellow)
This LED indicates the status of the reading phase.
(Figure A, 6)
COM
(yellow)
This LED indicates active communication on main serial
port. (Figure A, 5)
STATUS
(red)
This LED indicates a NO READ result. (Figure A, 4)
During the reader startup (reset or restart phase), all the LEDs blink for one second.
On the back of the reader near the cable, the “POWER ON” LED indicates the laser
scanner is correctly powered.
The screw holes on the body of the reader are for mechanical fixture (Figure A, 3).
17
Summary of Contents for DS2400N
Page 1: ...DS2400N REFERENCE MANUAL ...
Page 5: ...GLOSSARY 70 INDEX 74 v ...
Page 10: ...x ...
Page 20: ...DS2400N 1 b Operating mode selection and definition c Digital Outputs configuration 10 ...
Page 49: ...INSTALLATION 3 Figure 23 ID NET Network Connections with isolated power blocks 39 ...
Page 50: ...DS2400N 3 Figure 24 ID NET Network Connections with Common Power Branch Network 40 ...
Page 51: ...INSTALLATION 3 Figure 25 ID NET Network Connections with Common Power Star Network 41 ...