INSTALLATION
2
2.3 ELECTRICAL
CONNECTIONS
All DS1500 models are equipped with a cable terminated by a 15-pin male D-sub
high-density connector for connection to the power supply and input/output signals.
The details of the connector pins are indicated in the following table.
CAUTION
Do not connect GND and SGND to different (external) ground
references. GND and SGND are internally connected through
filtering circuitry which can be permanently damaged if subjected to
voltage drops over 0.8 Vdc.
Figure 5 - 15-pin D-sub High-Density Male Connector
15-pin D-sub HD male connector pinout
Pin Name Function
1
VS
Power supply input v
5
GND
Power supply input voltage -
8
PE
Protective Earth Ground
13 SHIELD Cable
Shield
9
EXT TRIG-
External Trigger -
7
OUT1 +
Output 1 +
14
OUT2 +
Output 2 +
11, 12, 15 NC
Not Connected
Pin RS232
RS485
Full-Duplex
RS485
Half-Duplex
2 TX232
Main
TX485-
RTX485-
3 RX232
Main
RX485+
6 TXAUX
TX485+
RX485-
4
Serial
interface
signals, see
SGND SGND SGND