Datalogic DLR-PR001 Series Quick Reference Manual Download Page 6

iv

DLR-PR001-XX

any time. Subject to the foregoing, termination shall be effective upon notice to the
other party. In the event that this Agreement terminates for any reason, End
User’s license to use the Software will immediately terminate, and End User must
immediately stop using the Software, destroy all copies of the Software and all of
its component parts, and, upon request, provide an affidavit certifying your compli-
ance with the foregoing. The provisions of Sub-sections 1.2, 1.3, 1.4, 1.5, 4, 5, 6, 8,
and 12 shall survive termination of this Agreement. 

4. Limited Warranty

Datalogic warrants that, under normal use and operation, the Software will con-
form substantially to the applicable Datalogic Product documentation for the
period specified in the same, provided that the Software is used with the Datalogic
Product. Datalogic’s entire liability and End User’s sole and exclusive remedy for
any breach of the foregoing limited warranty will be, at Datalogic’s option, the pro-
vision of a downloadable patch or replacement software. 
Datalogic does not warrant (i) that Software will meet End User's requirements; (ii)
that Software will be uninterrupted or defect error free; (iii) any non conformity
derived from unauthorized use, and/or improper installation or repair not in com-
pliance with Datalogic Product documentation. End User agrees that the existence
of such non conformities or errors and Datalogic’s inability to remedy such errors
shall not constitute a breach of this Agreement. 
EXCEPT AS PROVIDED IN THIS AGREEMENT, THE DATALOGIC PRODUCT IS PRO-
VIDED "AS IS" AND DATALOGIC MAKES NO WARRANTIES OF ANY KIND, EXPRESS
OR IMPLIED, WRITTEN OR ORAL, WITH RESPECT TO THE DATALOGIC PRODUCT OR
SOFTWARE, AND SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

5. Limitation Of Liability

EXCEPT AS PROVIDED IN THIS AGREEMENT, NEITHER DATALOGIC NOR ITS LICEN-
SORS SHALL BE LIABLE FOR ANY CLAIMS AGAINST END USER BY ANY OTHER
PARTY. IN NO EVENT SHALL DATALOGIC'S LIABILITY FOR DAMAGES, IF ANY,
WHETHER BASED UPON CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT
LIABILITY, STRICT LIABILITY, WARRANTY, OR ANY OTHER BASIS, EXCEED THE PRICE
OR FEE PAID BY END USER FOR THE DATALOGIC PRODUCT. UNDER NO CIRCUM-
STANCES SHALL DATALOGIC OR ITS LICENSORS BE LIABLE TO END USER OR ANY
THIRD PARTY FOR LOST PROFITS, LOST DATA, INTERRUPTION OF BUSINESS OR
SERVICE, OR FOR ANY OTHER SPECIAL, CONSEQUENTIAL, CONTINGENT, INDIRECT,
INCIDENTAL, PUNITIVE, EXEMPLARY, OR OTHER SIMILAR DAMAGES, EVEN IF DAT-
ALOGIC OR ITS LICENSORS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES. END USER MUST BRING ANY ACTION UNDER THIS AGREEMENT WITHIN
12 (TWELVE) MONTHS AFTER THE CAUSE OF ACTION ARISES.

6. Infringement

To the maximum extent permitted by law, End User agrees to defend, indemnify
and hold harmless Datalogic, its affiliates and their respective directors, officers,
employees and agents from and against any and all claims, actions, suits or pro-
ceedings, as well as any and all losses, liabilities, damages, costs and expenses
(including reasonable attorney’s fees) arising out of or accruing from or related to
Licensee’s failure to comply with the terms of this Agreement, including but not
limited to (1) non compliance with any applicable laws or regulations with Data-
logic product documentation, (2) unauthorized use or disclosure of Software, and
(3) use of Software in combination with software, hardware, systems, or other
items not provided by Datalogic.

7. Support

End User may request support for Software from Datalogic at Datalogic's standard
support fees and under Datalogic's standard support terms and conditions in
effect at the time the support is requested.

8. Government Restricted Rights; International Use

8.1 Use, duplication, or disclosure of the Software by the U.S. Government is sub-

ject to the restrictions for computer software developed at private expense as
set forth in the U.S. Federal Acquisition Regulations at FAR 52.227-14(g), or
52.227-19 or in the Rights in Technical Data and Computer Software clause at
DFARS 252.227-7013(c)(1)(ii), whichever is applicable.

8.2 If End User is using the Datalogic Product outside of the United States, End

User must comply with the applicable local laws of the country in which the
Datalogic Product is used and with U.S. export control laws,. Without prejudice
of the foregoing, the End User agrees to not export or re-export the Software,
any part thereof, or any process or service that is the direct product of the
Software to any country, person or entity subject to U.S. export restrictions.
End User specifically agrees not to export or re-export any of the Software: (i)

Summary of Contents for DLR-PR001 Series

Page 1: ...DLR PR001 XX Family RFID Portal Reader 4 Antennas EU US Quick Reference Guide ...

Page 2: ...n Should future revisions of this manual be published you can acquire printed versions by contacting your Datalogic representative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Datalogic publications please let us know via the Co...

Page 3: ...o the Reader via Ethernet 3 Mechanical Dimensions and Installation Notice 4 Kit and Accessories 5 External Interfaces Description 6 Connectors 6 Power Supply Connector 6 RS232 Port 7 Ethernet Port 8 USB Host Ports 9 GPIO Port 10 RFID Antenna Ports 11 LEDs 11 DLR PR001 XX Configuration 12 Restore Factory Default Settings 12 Technical Specifications 13 Datalogic Limited Factory Warranty 15 Support T...

Page 4: ...ii DLR PR001 XX NOTES ...

Page 5: ...r the third party from whom Datalogic has obtained a license right This Agreement does not grant to End User any intellectual property rights As used in this Agree ment the term purchase or its equivalent when applied to the Software shall mean acquire under license End User is not entitled to receipt or use of the source code of any licensed Software 1 4 Portions of the Datalogic Product are prot...

Page 6: ... PRODUCT UNDER NO CIRCUM STANCES SHALL DATALOGIC OR ITS LICENSORS BE LIABLE TO END USER OR ANY THIRD PARTY FOR LOST PROFITS LOST DATA INTERRUPTION OF BUSINESS OR SERVICE OR FOR ANY OTHER SPECIAL CONSEQUENTIAL CONTINGENT INDIRECT INCIDENTAL PUNITIVE EXEMPLARY OR OTHER SIMILAR DAMAGES EVEN IF DAT ALOGIC OR ITS LICENSORS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES END USER MUST BRING ANY ACT...

Page 7: ...which Open Source Software packages have source code provided or available 11 Notices All notices required or authorized under this Agreement shall be given in writing and shall be effective when received with evidence of receipt Notices to Datalogic shall be sent to the attention of Datalogic IP Tech S r l Legal IP Department Via San Vitalino 13 40012 Calderara di Reno Bologna Italy or such other...

Page 8: ... Singapore International Arbitration Centre SIAC in accordance with the Arbitration Rules of the Sin gapore International Arbitration Centre SIAC Rules for the time being in force which rules are deemed to be incorporated by reference in this clause The seat of the arbitration shall be Singapore The number of arbitrators will be three with each side to the dispute being entitled to appoint one arb...

Page 9: ...er from multiple sources such as Smart Card readers Barcode readers and other in field sensors All data can be handled locally through data buffering filtering and aggregation in order to directly provide decision making data to higher level Business Intelligence processes The same data can also trigger local actuators and screen displays for in field real time processes in a standalone mode As a ...

Page 10: ... port in External Interfaces description paragraph for more details Getting Started The DLR PR001 XX reader can be used with an Ethernet cable or with the standard serial port To begin you need first to download and install the NET framework 2 0 only if NET is not already installed on your PC Follow the steps below to familiarize yourself with the product 1 Download the latest version of the Demo ...

Page 11: ...se see the Product Reference Guide Connecting to the Reader via Ethernet You can connect to the DLR PR001 XX via Ethernet trough an Ethernet crossover cable By default the reader is configured with the static IP address 192 168 0 1 If your private network matches the default network configuration of the reader you can connect to it Otherwise you can change the network configuration of the reader b...

Page 12: ...Dimensions and Installation Notice The DLR PR001 XX could be mounted either horizontally or vertically Locate the four mounting slots on the reader as illustrated below All measurements are in millimeters Figure 1 DLR PR001 XX Technical drawing ...

Page 13: ...ription Part Number RFID PORTAL READER 4 ANTENNA EU DLR PR001 EU RFID PORTAL READER 4 ANTENNA US DLR PR001 US RFID PORTAL READER KIT EU DLR PR001 K1 EU RFID PORTAL READER KIT US DLR PR001 K1 US INTERFACE BOARD FOR I O IF DLR PR002 RFID ANTENNA FOR DLR PR001 EU AN DLR PR002 EU RFID ANTENNA FOR DLR PR001 US AN DLR PR002 US CONNECTION CABLE 5 MT FOR DLR PR002 CAB 002 CONNECTION CABLE 15 MT FOR DLR PR...

Page 14: ...r Supply Connector The power supply connector shall be used to provide the reader with the DC supply voltage in the range 9V to 36V The part number of the connector is KPJX 3S S by Kycon the pinout of the connector is shown in the following table The external shield can be connected to Ground Figure 4 Power supply connector Pin Signal Description 1 GND Ground 2 V DC input Voltage 3 GND Ground ...

Page 15: ...ng Figure 5 RS232 port DB9 socket connector pinout NOTE It is strongly recommended to use only the Dat alogic power supply AC DC adapter 24Vdc out put voltage Pin Signal Description 1 Not connected 2 TX TX output 3 RX RX input 4 Not connected 5 GND Ground 6 Not connected 7 CTS Clear to Send 8 RTS Req to send 9 Not connected Shell Ext shell conn To GND ...

Page 16: ...The Ethernet connector pinout is the following Figure 6 Ethernet connector Pin Signal Description 1 DA Bidirectional pair A 2 DA Bidirectional pair A 3 DB Bidirectional pair B 4 DC Bidirectional pair C 5 DC Bidirectional pair C 6 DB Bidirectional pair B 7 DD Bidirectional pair D 8 DD Bidirectional pair D NOTE The DLR PR001 does not support Power Over Ethernet POE ...

Page 17: ...o connect external devices like Wi Fi or Bluetooth adapters GPS receivers or flash pen drives Each port is able to provide up to 500mA supply current at 5VDC voltage The connector is a 4 pins Type A receptacle Figure 7 USB connector type A Pin Signal Description 1 Vbus 5V DC USB bus 2 D D signal 3 D D signal 4 GND Ground Shell External shell ...

Page 18: ...re 8 DB15 Socket Connector Pin Signal Description 1 GPIO0 General Purpose I O 0 2 GPIO2 General Purpose I O 2 3 GPIO4 General Purpose I O 4 4 GPIO6 General Purpose I O 6 5 GPIO8 General Purpose I O 8 6 GPIO10 General Purpose I O 10 7 GPIO12 General Purpose I O 12 8 GND Ground 9 GPIO1 General Purpose I O 1 10 GPIO3 General Purpose I O 3 11 GPIO5 General Purpose I O 5 12 GPIO7 General Purpose I O 7 ...

Page 19: ...op cover panel houses the following LEDs LED Function Type POWER Power ON Green LED RF ACTIVE RFID Transmitting activity Blink Yellow LED GSM GPRS Not Present No LED FAULT Boot phase Red LED Ready to work OFF ANTENNA The LED indicates the antenna configured via software to transmit By default the selected antenna is Ant1 Please note that the LED does not indicate if an antenna is physically attach...

Page 20: ...al terminal monitor Hyperterminal Tera Term Putty etc with the following settings Baud rate 115200 b s Data bit 8 Stop bit 1 Parity none Flow control none To login type root in the Username text box and rooroot as Password For more details and complete procedure for reader configuration using the serial port please see the Products Reference Guide Restore Factory Default Settings Restoring factory...

Page 21: ...an standard ETSI EN 302 208 902 00 928 00 MHz US standard FCC part 15 RF Output Power Up to 32 dBm 1 6W conducted ETSI Up to 30 dBm 1W conducted FCC Antenna Up to 4 external antennas RP TNC connectors Receiving Capability Gen 2 Dense Reader Mode Management Data rate up to 400 Kb s Technical Characteristics CPU Intel Atom Z510 CPU 1 1 Ghz Memory 2 Gbytes RAM 8 Gbytes MicroSD Operating System Linux ...

Page 22: ...Technical Specifications 14 DLR PR001 XX Operat Temperature 10 C to 50 C 14 F to 122 F Storage Temperature 20 C to 60 C 4 F to 140 F ESD Level 16kV Item Description ...

Page 23: ...ll extend from the date of shipment from Datalogic for the duration published by Datalogic for the product at the time of purchase Warranty period Datalogic warrants repaired hardware devices against defects in workmanship and materials on the repaired assembly for a 90 day period starting from the date of shipment of the repaired product from Datalogic or until the expiration of the original warr...

Page 24: ... v any defect or damage caused by natural or man made disaster such as but not limited to fire water damage floods other natural disasters vandalism or abusive events that would cause internal and external compo nent damage or destruction of the whole unit consum able items vi any damage or malfunctioning caused by non restoring action as for example firmware or software upgrades software or hardw...

Page 25: ...CE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES Risk of Loss Customer shall bear risk of loss or damage for product in transit to Datalogic Datalogic shall assume risk of loss or damage for product in Datalogic s possession In the absence of specific written instructions for the return of product to Customer Datalogic will select the carrier but Datalogic shall not thereby assume any liability in con...

Page 26: ...SUPPORT RFID category link From this page you can select your product model from the dropdown list which gives you access to Downloads including Data Sheets Manuals Software Utilities and Drawings Repair Program for On Line Return Material Authoriza tions RMAs plus Repair Center contact information Service Program containing details about Maintenance Agreements Technical Support through email or p...

Page 27: ...Support Through the Website Quick Reference Guide 19 NOTES ...

Page 28: ...nd the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S and the E U Datalogic S r l Via San Vitalino 13 Calderara di Reno BO 40012 Italy Telephone 39 051 3147011 Fax 39 051 3147205 www datalogic com 820098414 Rev A September 2017 ...

Reviews: