INSTALLATION
31
2
2.7.3 Auto PackTrack Setup
After setting the initial parameters in the PackTrack menu the Auto PackTrack setup
procedure can be started:
1. Press
Enter
at the
Start
item in the
PackTrack
menu.
2. Press
Enter
to confirm the action. The SC6000 sends the message to the Slave
scanners and the Display shows the
Wait
message.
After receiving the answer from all of the Slaves, the SC6000 shows the status of
each node (of each scanner of the cluster) as in the example below.
S c
a
n
I
I
I
U
I
I
I
I
S
t
a
t
e
A B C D E F G H
The slave scanners are listed as letters only (
A
,
B
,
C
, etc.) independently from the
selection in the
System Information Section>User Interface Style
configuration
parameter in Genius™.
Above each scanner position a symbol indicates the scanner status according to the
following convention:
U
cannot be calibrated
not supported by scanner software version
U
can be calibrated
can be calibrated but the calibration procedure fails
either barcode reading or verification
L
Lost
scanner stops responding during the procedure
I
Initial State
scanner ready to be calibrated
N
Not Verified
scanner calibrated but not verified
C
Calibrated
scanner is calibrated
3. At this point the SC6000 display allows to
Continue
or to
Stop
the procedure. You
can switch between the previous display windows using the
Up
or
Down
arrow keys.
If there are any nodes that show as
U
or
L
, then you should
Stop
the procedure and
correct the problem.
If the nodes respond with
I
,
N
, or
C
then you can
Continue
with the procedure.
4. Press
Enter
to
Continue
the procedure. The SC6000 shows message
Let the parcel
run
.
5. Place the PCT-8000 onto the moving conveyor, before the PS Line (reference point)
and parallel to a conveyor edge (i.e. right-hand edge) with its arrow in the same
direction as the conveyor movement. Let it pass through the reading station. The
SC6000 shows the
Wait
message.