DM4170 – Installation Manual
Installing the DM4170
204.4308.03
20
Figure 14 – DC Power Connector Pin Settings
3.10.2
Power Cables
3.10.2.1
PSU 125 AC
The PSU 125 AC includes a 3-meter power cord in the standard female IEC 320/C14 for the
NBR 14136 plug.
3.10.2.2
PSU 125 DC
The PSU 125 includes a 3.5 meter DC power cable in the PP 1 mm
2
gauge standard
with both
ends open and the TERMINAL BLOCK standard male connector (normally shipped screwed to
the PSU 125 DC) for the installation of the cable.
Follow the information below to install the cable to the Terminal Block connector:
Step 1
•
Remove the TERMINAL BLOCK connector from the PSU 125 DC by unscrewing
the two side screws of the connector using a 1/8" screwdriver (number 0) as
shown below:
Figure 15 – Removing the TERMINAL BLOCK from the PSU 125 DC
Step 2
•
Locate the power cord shipped with the PSU 125 DC and cut it to the desired
preferred length. If the cable needs to be replaced, it is important that it have a
gauge of 1mm
2
or higher, and that the conductor colors follow the