background image

 

 

 

 

21 

 

DT-ATSC-QAM-8V2 Manual 

DATATRONIX 1-Year Limited Warranty 

DATATRONIX. (the "Company") warrants to the Original Purchaser that the item purchased is 

free from defects in workmanship or material under normal use. This warranty starts on the date 

of shipment of the hardware to the Original Purchaser. 
During the warranty period, the Company agrees to repair or replace, at its sole option, without 

charge to Original Purchaser, any defective component. To obtain service, the Original 

Purchaser must return the item to the Company properly packaged for shipping. All defective 

products must be returned to the Company within thirty (30) days of failure. Products must be 

returned with a description of the failure and Return Merchandise Authorization (RMA) number 

supplied by the Company. To receive a RMA number and a return shipping address on where to 

deliver the hardware, call 610-429-1821. The shipping, and insurance charges incurred in 

shipping to the Company will be paid by Original Purchaser, and all risk for the hardware shall 

remain with the Original Purchaser until such time as Company takes receipt of the hardware. 

Upon receipt, the Company will promptly repair or replace the defective unit, and then return 

said unit to Original Purchaser, shipping prepaid. The Company may use reconditioned or like-

new parts or units, at its sole option, when repairing any hardware. Repaired products shall 

carry the same amount of outstanding warranty as from original purchase. Any claim under the 

warranty must include dated proof of purchase or invoice. In any event, the Company's liability 

for defective hardware is limited to repairing or replacing the hardware. 
This warranty is contingent upon proper use of the hardware by Original Purchaser and does 

not cover: if damage is due to Acts of God (including fire, flood, earthquake, storm, hurricane or 

other natural disaster), accident, unusual physical, electrical, or electromechanical stress, 

modifications, neglect, misuse, operation with media not approved by the Company, tampering 

with or altering of the hardware, riot, war, invasion, act of foreign enemies, hostilities (regardless 

of whether war is declared), civil war, rebellion, revolution, insurrection, military or usurped 

power or confiscation, terrorist activities, nationalization, government sanction, blockage, 

embargo, labor dispute, strike, lockout or interruption or failure of electricity, air conditioning, or 

humidity control, internet, network,  or telephone service 
The warranties given herein, together with any implied warranties covering the hardware, 

including any warranties of merchantability or fitness for a particular purpose, are limited in 

duration to one year from the date of shipment to the Original Purchaser. Jurisdictions vary with 

regard to the enforceability of warranty limitations, and you should check the laws of your local 

jurisdiction to find out whether the above limitation applies to you. 
The Company shall not be liable to your for loss of data, loss of profits, lost savings, special, 

incidental, consequential, indirect, or other similar damages arising from breach of warranty, 

breach of contract, negligence, or other legal action even if the Company or its agent has been 

advised of the possibility of such damages, or for any claim brought against your by another 

party. Jurisdictions vary with regard to the enforceability of provisions excluding or limiting 

liability for incidental or consequential damages. You should check the laws of your local 

Summary of Contents for DT-ATSC-QAM-8V2

Page 1: ...Manual 8 input ATSC 8VSB QAM B to QAM B Trans Modulator DT ATSC QAM 8V2 User Manual...

Page 2: ...GUI Interface 6 Factory Default IP 192 168 1 9 6 System Setup via GUI Interface 6 Name admin Password Admin123 6 Overview Page 7 9 Ingest Setup 10 Streaming Setup 11 Streaming System Parameters 12 Cu...

Page 3: ...ated power supply The use of any other power supply could cause damage and invalidate the manufacturer s warranty DO NOT connect the power cord to the device if the power cord is damaged DO NOT cut th...

Page 4: ...ive and process up to 8 individual 8VSB ATSC Clear QAM channels along with up to 56 sub channels and easily convert these signals to produce a high quality RF QAM distribution system The DT ATSC QAM 8...

Page 5: ...e 57 to 861 MHz Under STD Mode 8 Independent RF Frequencies Channels Bandwidth 6 MHz Output Level 45 dBmV Typical Output Impedance 75 ohm Level Adjustment 0 to 20 dB VCN Auto Major Minor Manual Major...

Page 6: ...Cable directly to the Utility Port on the rear panel of the device or connect the Ethernet cable to an Ethernet switch Connect an Ethernet cable to Your PC Laptop 2 Modify Your PC Laptop IPV4 address...

Page 7: ...w Page provides an overall system status of the DT ATSC QAM 8V2 including RF Input Type Frequency SNR Signal Status and Programs Programs If you move your cursor to you will see the detailed informati...

Page 8: ...8 DT ATSC QAM 8V2 Manual Overview RF Output RF Outputs showing the number of sub streams programs...

Page 9: ...9 DT ATSC QAM 8V2 Manual Overview Fan This tab shows fan status and system uptime...

Page 10: ...ngest input 1 thru 8 Enable as required 3 Select Standard ATSC or QAM ATSC 8VSB QAM STD QAM HRC QAM IRC 4 Select Constellation For QAM select 64 QAM or 256 QAM as required 5 Select Frequency MHz Input...

Page 11: ...Name 1 16 Characters 5 Select VCN Mode VCN Mode 2 Part Auto Example 102 1 Set Automatically by the Device VCN Mode 2 Part Manual 102 2 Manual Entry by User VCN Mode 1 Part Manual 102 Manual Entry by U...

Page 12: ...ID Service ID Program ID Short Name From Content Provider Long Name From Content Provider Bit Rate Input Bit Rate Output SID Service ID Definable PMT PID Program Map Table PID Video PID Video Stream P...

Page 13: ...ew The Streaming Setup parameters page is easily customizable for each system To customize the parameters shown 1 Select Select Columns tool 2 Add or remove parameter as needed by selecting or deselec...

Page 14: ...tion 0 20dB 1dB Steps 9 Select constellation 64 QAM 256 QAM 10 Select interleaver change as required Default I 128 J 1 11 Save and Confirm all changes Note 1 Bitrate Mbps shown allows the integrator t...

Page 15: ...he IP address of the device 2 Modify hostname as required 3 Select DHCP or static IP 4 For Static IP select static IP and enter static IP address for device 5 Enter Subnet Mask 6 Enter Default Gateway...

Page 16: ...the reset button once the power LED stops flashing and become static green 4 Unit s IP address will revert back to default IP 192 168 1 9 5 Unit s login data will revert back to factory default Name...

Page 17: ...ct time zone from the drop down tool 3 Enter NTP Server 1 2 addresses as required 4 Select synchronize system with PC clock as required 5 Select apply to apply all changes Administration Reboot Use th...

Page 18: ...etup Streaming Setup RF Out Setup Network Setup System Setup 4 Locate and Name file for future use Note The backup can be imported to assist in setting up new or multiple devices onsite Remember to Sa...

Page 19: ...administration tab 2 Select firmware upgrade tab 3 Browse to locate the required image file to be uploaded 4 Select Upload to import the selected file into the device Note Do not power off the unit w...

Page 20: ...device that performs Network Address Translation Anyone can us private addresses and they are not required to seek permission to use them Again networks using private IP addresses cannot communicate d...

Page 21: ...r replacing the hardware This warranty is contingent upon proper use of the hardware by Original Purchaser and does not cover if damage is due to Acts of God including fire flood earthquake storm hurr...

Page 22: ...nties whether oral or written The agents employees distributors and dealers of the Company are not authorized to make modification to this warranty or additional warranties binding on the Company Acco...

Reviews: