FALCON 7X
02-24-40
CODDE 1
PAGE 1
/ 6
DGT 97831
ATA 24 – ELECTRICAL POWER
GROUND OPERATION
ISSUE 2
DASSAULT AVIATION Proprietary Data
GROUND POWER CONNECTOR
The ground power receptacle located behind the ground power panel on the RH side of the
lower fuselage enables a 28VDC external ground power unit to be connected to the airplane.
The connection of external power to the distribution system is controlled from the Overhead
Panel.
A switched circuit breaker located inside the ground power panel adjacent to the ground
power receptacle provides protection and will automatically trip if power quality is not
acceptable.
FIGURE 02-24-40-00 - GROUND POWER RECEPTACLE
The normal sequence of events for connecting ground power to the airplane is to open the
ground power panel and connector the 28 volt DC plug into the power receptacle, select the
ground power ON/OFF toggle action switch to ON, enter the flight deck and select EXT
POWER pushbutton on the OP.
¾
Refer to Ground Servicing manual.