02-24-05
FALCON 7X
PAGE 4
/ 6
CODDE 1
ISSUE 2
ATA 24 – ELECTRICAL POWER
GENERAL
DGT97831
DASSAULT AVIATION Proprietary Data
FLIGHT DECK OVERVIEW
CONTROLS
Crew has control over the electrical system via:
-
The " DC SUPPLY" Panel on the overhead panel,
-
The CB sub page of the ELEC synoptic,
-
Two switches on the Emergency Panel (aft end of the pedestal) for RAT inhibit and "RH
ESS ISOL",
-
The RAT Manual Release Handle (right side of the pedestal),
-
The Fire Control Panel in case of engine fire, to confirm generator disconnection,
-
The Servicing sub page of TEST synoptic for "ground servicing bus".
NOTE
Circuit Breakers are not accessible in the cockpit. CB are installed in the different Distribution
Boxes. The "CB page" of the ELEC synoptic allows modifying status of electronic CB on ground
only. In flight, the "CB page" provides the status of the mechanical and electronic CB.
INDICATIONS
Indications related to the Electrical System configuration and status are displayed in:
-
The "DC SUPPLY" Panel ( on the overhead panel ),
-
The ELECtrical System Synoptic and subpage "Circuit Breaker",
-
The TEST synoptic page,
-
The ENG-CAS window for CAS messages,
-
The STATus synoptic / FAULT tab for fault messages.