18
Cleaning compound (Storage-2 or Storage-3) must be mixed with fresh water at a ratio of 1 con-
tainer of compound to 3 gallons (12L) of unchlorinated water to have the proper solution. About
two gallons (8L) of water is already present inside an Versa Sea Pak system. This water has to be
figured into the mixture. A Versa Sea Pak system will use one container of compound.
Note: Procedures are the same for the Storage-2 and Storage-3 cleaners
Cleaning Procedure:
1. Make 4 gallons of water into a bucket or obtain 4 gallons of Chlorine free fresh water.
2. Flush the system as shown in the Normal Operation Section. Leave one Gallon of water in
the bucket.
3. Connect your inlet service hose, brine discharge service hose, and product hose and place
them in the bucket.
4.
Make sure that the pressure relief valve is OPEN
(un-pressurized).
5. Mix the cleaning chemical in the bucket.
6. Start the system and circulate the chemical through the system for 20 minutes.
7. Allow the system to soak for an hour, or more if the chemicals are cold.
8. Run the pump for another 20 minutes.
9. Stop the pump, replace the brine discharge hose and start the pump until the bucket is
empty.
10. Flush the system using the instructions for “New System Startup”
Heating the water is preferable. One way to do this is to find a camp stove and use a large
stainless steel pot to heat the solution in. The cleaning solution throughout the system will
heat as it circulates in and out of the pot. An alternative is to heat the one or two gallons of
initial water to 120° on the main stove before mixing in the cleaner and circulating it into the
system. Periodically stop and reheat the solution.
.