background image

 

WL100

 Manual                                                                     Page 50                                                                      Revision: 1‐14‐2019 

DISPENSING TROUBLESHOOTING INDEX 

 

  

1.

 

Irregular / Intermittent Dispensing from One Side 
 

2.

 

Dispensing won't stop when not holding the Dispensing Button 
 

3.

 

Steady Drip out of Faucet 
 

4.

 

Hot Water or Steam coming out of both the Faucet and the Vent Hole 
 

5.

 

Hot Water coming out of Faucet Vent Hole 
 

6.

 

Restricted Flow of Hot Water  
 

7.

 

Hot Water Drip out of Faucet 
 

8.

 

Dispenses Hot and Cold Water at the same time 
 

9.

 

No cold water available 
 

10.

 

Water does not dispense from unit 
 

11.

 

Cold Water dispenses from Faucet and Vent Outlet Simultaneously 
 

12.

 

Small amount of water periodically dispenses from faucet automatically 
 

13.

 

Dispense Buttons Stick 
 

14.

 

Run‐On ‐ Water continues to dispense out of faucet after releasing the dispense 
button 

  

 

Also includes related instruction for Hot Tank Descaling 

 

 
 

 

 

Summary of Contents for WL100

Page 1: ...of Faucet Vent Hole 6 Restricted Flow of Hot Water 7 Hot Water Drip out of Faucet 8 Dispenses Hot and Cold Water at the same time 9 No cold water available 10 Water does not dispense from unit 11 Col...

Page 2: ...button Does the Solenoid open without water pressure to the unit Listen for Solenoid to activate not to mistaken for the button click Adjust water pressure to 40 60 psi The correct input water pressu...

Page 3: ...ust water pressure to 40 60 psi The correct input water pressure is critical to the performance of the unit to allow Solenoids to open Stem of the switch is broken on the PCB Printed Circuit Board Rem...

Page 4: ...sure gauge Additional method of verification is to turn off water to unit and press the dispense button Does the Solenoid open without water pressure to the unit Listen for Solenoid to activate not to...

Page 5: ...it Inspect and replace tubing as necessary Faucet nipple screen mesh has obstruction s Unscrew faucet nipple from faucet and remove any obstruction s from screen mesh Exhausted Filter Replace the Filt...

Page 6: ...in its base This ensures the reservoir is always full by allowing more water in than out There is a small hole in the side of the tank outlet tube that allows air and water to pass into the vent chamb...

Page 7: ...without water pressure to the unit Listen for Solenoid to activate not to mistaken for the button click Adjust water pressure to 40 60 psi The correct input water pressure is critical to the performa...

Page 8: ...n click Adjust water pressure to 40 60 psi The correct input water pressure is critical to the performance of the unit to allow Solenoids to open Closed Water Supply Valve Open the Water Supply Valve...

Page 9: ...nput water pressure is critical to the performance of the unit to allow Solenoids to open Closed Water Supply Valve Open the Water Supply Valve The unit is not properly plugged into electrical outlet...

Page 10: ...ater pressure at the inlet bulkhead with a water pressure gauge Additional method of verification is to turn off water to unit and press the dispense button Does the Solenoid open without water pressu...

Page 11: ...has an outlet restrictor to ensure the tanks remain full of water and water is controlled as it is released to the faucet The inlet Solenoid controls flow into the tanks The tanks will depressurize on...

Page 12: ...ng solution is compatible with stainless and always flush the unit completely Dispose in an environmentally safe manner Materials Needed Personal Protective Equipment Rubber or Nitrile Safety Gloves a...

Page 13: ...Filters WARNING HOT WATER Unit produces Hot Water up to 87o C 189o F Water above 52o C 125o F can cause severe burns or scalding Hot water should be dispensed carefully into insulated container to avo...

Reviews: