Hot Water or Steam Coming out of both the Faucet and Vent Hole 

 
 

Possible Reason 

Solution 

Improper Tubing attachment 
from the Hot Tank to faucet or 
vice versa. 

Check that the Tubing is connected from Tank Outlets to correct 
Faucet attachments.  Connect Tubing to Outlets as needed. 

 

5.

 

Hot Water Coming out of Faucet Vent Hole 

 
 

Possible Reason 

Solution 

Too much water pressure.  
Recommend 40 to 60 psi for 
the 

WL100 Water Treatment 

System 

to operate properly. 

Check water pressure at the inlet bulkhead with a water pressure 
gauge. 
 
Additional method of verification is to turn off water to unit and 
press the dispense button.  Does the Solenoid open without water 
pressure to the unit?  Listen for Solenoid to activate, not to 
mistaken for the button “click”. 
 
Adjust water pressure to 40‐60 psi.  

The correct input water 

pressure is critical to the performance of the unit to allow 
Solenoids to open. 

 

Improper tubing attachment 
from the tank to faucet or vice 
versa. 

Verify tubing is connected properly from tank outlets to correct 
faucet attachments. 

Hot Tank outlet hole is scaled 
over. 

Inspect and Descale Tank as needed. 
 

See Hot Tank Descaling Instructions that are included further 
below in this Troubleshooting Section. 

 

Expansion chamber is not 
sealed properly. 

Replace the Hot Tank.   

 

 

 

Summary of Contents for WL100

Page 1: ...of Faucet Vent Hole 6 Restricted Flow of Hot Water 7 Hot Water Drip out of Faucet 8 Dispenses Hot and Cold Water at the same time 9 No cold water available 10 Water does not dispense from unit 11 Col...

Page 2: ...button Does the Solenoid open without water pressure to the unit Listen for Solenoid to activate not to mistaken for the button click Adjust water pressure to 40 60 psi The correct input water pressu...

Page 3: ...ust water pressure to 40 60 psi The correct input water pressure is critical to the performance of the unit to allow Solenoids to open Stem of the switch is broken on the PCB Printed Circuit Board Rem...

Page 4: ...sure gauge Additional method of verification is to turn off water to unit and press the dispense button Does the Solenoid open without water pressure to the unit Listen for Solenoid to activate not to...

Page 5: ...it Inspect and replace tubing as necessary Faucet nipple screen mesh has obstruction s Unscrew faucet nipple from faucet and remove any obstruction s from screen mesh Exhausted Filter Replace the Filt...

Page 6: ...in its base This ensures the reservoir is always full by allowing more water in than out There is a small hole in the side of the tank outlet tube that allows air and water to pass into the vent chamb...

Page 7: ...without water pressure to the unit Listen for Solenoid to activate not to mistaken for the button click Adjust water pressure to 40 60 psi The correct input water pressure is critical to the performa...

Page 8: ...n click Adjust water pressure to 40 60 psi The correct input water pressure is critical to the performance of the unit to allow Solenoids to open Closed Water Supply Valve Open the Water Supply Valve...

Page 9: ...nput water pressure is critical to the performance of the unit to allow Solenoids to open Closed Water Supply Valve Open the Water Supply Valve The unit is not properly plugged into electrical outlet...

Page 10: ...ater pressure at the inlet bulkhead with a water pressure gauge Additional method of verification is to turn off water to unit and press the dispense button Does the Solenoid open without water pressu...

Page 11: ...has an outlet restrictor to ensure the tanks remain full of water and water is controlled as it is released to the faucet The inlet Solenoid controls flow into the tanks The tanks will depressurize on...

Page 12: ...ng solution is compatible with stainless and always flush the unit completely Dispose in an environmentally safe manner Materials Needed Personal Protective Equipment Rubber or Nitrile Safety Gloves a...

Page 13: ...Filters WARNING HOT WATER Unit produces Hot Water up to 87o C 189o F Water above 52o C 125o F can cause severe burns or scalding Hot water should be dispensed carefully into insulated container to avo...

Reviews: