background image

 

OPERATING DETERMINATIONS 

 

This system is not designed for permanent operation. Consistent operation breaks will ensure that the 
system will serve you for a long time without defects. 

 

If this system is operated in any other way, than the one described in this manual, the product may suffer 
damages and the

 

warranty becomes void.  

Any other operation may lead to dangers like short-circuit, burns, electric shock, etc. 
 
You endanger your own safety and the safety of others! 

 

Improper installation can cause serious damage to people and property !

 

 

 

Connection with the mains

 

 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place. 

 

International 

EU (including UK) 

From April 2004 

North America 

Pin 

Brown 

Black 

Phase  

Blue 

White 

Neutral 

 

Green/Yellow 

Green 

Protective Earth 

 

Make sure that the device is always connected 

properly

 to earth!  

 
 

      Return Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 

 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

1) Your name 
2) Your address 
3) Your phone number 
4) A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
 It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 

Summary of Contents for TAS-2400

Page 1: ...TAS 2400 V2 ORDERCODE D4193...

Page 2: ...P Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our c...

Page 3: ...Unpacking Instructions Safety instructions Operating Determinations Return Procedure Claims Description Features and Overview Overview Front panel Overview Back panel Operation Mode selection Connect...

Page 4: ...not use the system To maintain perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Pleas...

Page 5: ...the electrical system ground Connecting amplifier outputs to oscilloscopes or other test equipment while the amplifier is in bridged mode may damage both the amplifier and test equipment Do not drive...

Page 6: ...roperly pack fixture any shipping damage resulting from inadequate packaging is the customer s responsibility Highlite reserves the right to use its own discretion to repair or replace product s As a...

Page 7: ...e Features The DAP TAS 2400 is a 2U High Power SMPS Triple Class H Stereo PA Amplifier Light weight High power touring Amplifier Switch mode Power supply Roadproof housing Intelligent signal indicator...

Page 8: ...threshold Continuous illumination also indicates that ACL Active Clip Limiting protection circuitry is engaged 9 Channel 2 volume scale indicator This indicator displays the volume attenuation of Chan...

Page 9: ...s accept input signals on XLR input plugs See the section on connecting cables on page 11 12 for information on polarity Connectors for each channel are in parallel The unused connectors may be used f...

Page 10: ...a 240VAC 50Hz South America 120VAC 60Hz or 220VAC 50Hz Japan 1OOVAC 50Hz NOTE Always turn off and disconnect the amplifier from mains voltage before making audio connections Also as an extra precautio...

Page 11: ...signal at Channel B s input produces output at Channel B s output Fig 6 Important Absolute minimum nominal load Impedance for stereo operation is 2 Ohm per channel Parallel Mode When set to Parallel M...

Page 12: ...ame setting Only channel A input may be used Use extreme caution when operating the amplifier In Bridged Mono Mode Never ground either side of the speaker cable when the amplifier Is in Bridged Mono M...

Page 13: ...em This gives the advantage of increasing their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using un...

Page 14: ...n the fuse cover Gently pry up the fuse cover The fuse will come out 3 Remove the broken fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was...

Page 15: ...tage 22 dBu Input Impedance 20 KOhm Balanced 10 KOhm Unbalanced Protection Soft Start High Temperature Clip Limiter Fixed Soft Clip Selectable Short Circuit Input Overload Output Overload Over Current...

Page 16: ...1 16 2 3 4 5 1 5 0 58 1 16 2 3 2 5 0 35 0 7 1 39 4 0 22 0 44 0 87 5 0 5 4 3 8 2 15 5 0 75 2 9 5 6 10 8 1 5 1 45 2 9 5 6 2 5 0 87 1 74 3 4 4 0 55 1 09 2 2 6 0 37 0 73 1 45 10 0 5 8 24 15 5 28 0 75 5 6...

Page 17: ...load 5 18 0 81 1 61 3 2 16 0 51 1 02 2 14 0 32 0 64 1 28 12 0 2 0 4 0 8 10 0 128 0 25 0 51 10 18 1 61 3 2 6 2 16 1 02 2 4 14 0 64 1 28 2 5 12 0 4 0 8 1 6 10 0 25 0 51 1 01 40 18 6 2 11 9 22 16 4 7 7 1...

Page 18: ...2009 DapAudio...