background image

 

WARNING 

 
 
 
 
 

Unpacking Instructions 

Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure 
that all parts are present, and have been received in good condition. Notify the dealer immediately and 
retain packing material for inspection if any parts appear damaged from shipping or the carton itself 
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be 
returned to the factory, it is important that the fixture be returned in the original factory box and packing. 

 
Your shipment includes: 

• DAP TAS-2400 
• User manual

 

 

WARNING 

 
 
 
 
 
 
 

SAFETY INSTRUCTIONS 

Every person involved with the installation, operation and maintenance of this system have to: 

-

 

be qualified 

-

 

follow the instructions of this manual 

 
 
 

 

 
 
 

Before you initial start-up, please make sure that there is no damage caused by transportation. Should 
there be any, consult your dealer and do not use the system. 
 
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes written in this manual. 
 
Please consider that damages caused by manual modifications to the system are not subject to 
warranty. 
 
This system contains no user-serviceable parts. Refer servicing to qualified technicians only. 
 

IMPORTANT:

 

The manufacturer will not accept liability for any resulting damages caused by the non-
observance of this manual or any unauthorized modification to the system. 

 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Do not insert objects into air vents. 

CAUTION! 

 

Keep this system away from rain and moisture! 

 

CAUTION! Be careful with your operations. 

With a dangerous voltage you can suffer 

a dangerous electric shock when touching the wires!

 

 

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY  

BEFORE YOUR INITIAL START-UP!

 

 

Summary of Contents for TAS-2400

Page 1: ...TAS 2400 V2 ORDERCODE D4193...

Page 2: ...P Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our c...

Page 3: ...Unpacking Instructions Safety instructions Operating Determinations Return Procedure Claims Description Features and Overview Overview Front panel Overview Back panel Operation Mode selection Connect...

Page 4: ...not use the system To maintain perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Pleas...

Page 5: ...the electrical system ground Connecting amplifier outputs to oscilloscopes or other test equipment while the amplifier is in bridged mode may damage both the amplifier and test equipment Do not drive...

Page 6: ...roperly pack fixture any shipping damage resulting from inadequate packaging is the customer s responsibility Highlite reserves the right to use its own discretion to repair or replace product s As a...

Page 7: ...e Features The DAP TAS 2400 is a 2U High Power SMPS Triple Class H Stereo PA Amplifier Light weight High power touring Amplifier Switch mode Power supply Roadproof housing Intelligent signal indicator...

Page 8: ...threshold Continuous illumination also indicates that ACL Active Clip Limiting protection circuitry is engaged 9 Channel 2 volume scale indicator This indicator displays the volume attenuation of Chan...

Page 9: ...s accept input signals on XLR input plugs See the section on connecting cables on page 11 12 for information on polarity Connectors for each channel are in parallel The unused connectors may be used f...

Page 10: ...a 240VAC 50Hz South America 120VAC 60Hz or 220VAC 50Hz Japan 1OOVAC 50Hz NOTE Always turn off and disconnect the amplifier from mains voltage before making audio connections Also as an extra precautio...

Page 11: ...signal at Channel B s input produces output at Channel B s output Fig 6 Important Absolute minimum nominal load Impedance for stereo operation is 2 Ohm per channel Parallel Mode When set to Parallel M...

Page 12: ...ame setting Only channel A input may be used Use extreme caution when operating the amplifier In Bridged Mono Mode Never ground either side of the speaker cable when the amplifier Is in Bridged Mono M...

Page 13: ...em This gives the advantage of increasing their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using un...

Page 14: ...n the fuse cover Gently pry up the fuse cover The fuse will come out 3 Remove the broken fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was...

Page 15: ...tage 22 dBu Input Impedance 20 KOhm Balanced 10 KOhm Unbalanced Protection Soft Start High Temperature Clip Limiter Fixed Soft Clip Selectable Short Circuit Input Overload Output Overload Over Current...

Page 16: ...1 16 2 3 4 5 1 5 0 58 1 16 2 3 2 5 0 35 0 7 1 39 4 0 22 0 44 0 87 5 0 5 4 3 8 2 15 5 0 75 2 9 5 6 10 8 1 5 1 45 2 9 5 6 2 5 0 87 1 74 3 4 4 0 55 1 09 2 2 6 0 37 0 73 1 45 10 0 5 8 24 15 5 28 0 75 5 6...

Page 17: ...load 5 18 0 81 1 61 3 2 16 0 51 1 02 2 14 0 32 0 64 1 28 12 0 2 0 4 0 8 10 0 128 0 25 0 51 10 18 1 61 3 2 6 2 16 1 02 2 4 14 0 64 1 28 2 5 12 0 4 0 8 1 6 10 0 25 0 51 1 01 40 18 6 2 11 9 22 16 4 7 7 1...

Page 18: ...2009 DapAudio...

Reviews: