DAPAudio PM-Six Manual Download Page 5

 

  

 

 

   

 

Ordercode: D6182 

PM-Six

 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected] 

and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
 It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 

 

 

Summary of Contents for PM-Six

Page 1: ...PM Six V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D6182 MANUAL ENGLISH ...

Page 2: ...s 3 Return Procedure 4 Claims 4 Description of the device 5 Frontside 5 Backside 6 Installation 7 Set Up and Operation 8 Paging Function 8 Message Bank 8 Updating Chime 8 Connecting the PM Six to the ZPA 6240TU 100V Amplifier 8 Data Cabling 9 How to make a data cable 9 Maintenance 9 Troubleshooting 9 Product Specifications 10 ...

Page 3: ...x and packing Your shipment includes DAP Audio PM Six User manual Safety Instructions Every person involved with the installation operation and maintenance of this system has to be qualified follow the instructions of this manual Before the initial start up please make sure that there is no damage caused by transportation Should there be any consult your dealer and do not use the system To maintai...

Page 4: ...e your system Leave the system switched off until it has reached room temperature If your Dap Audio device fails to work properly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Dap Audio dealer for service Repairs servicing and electric connection must be carried out by a qualified technician WARRANTY Till one year after date of...

Page 5: ...ber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merc...

Page 6: ...iliary input for connecting external audio sources AES digital audio transmission of the PM Six ensures the best quality over longer distance cables Features Microphone unit condenser Frequency response 22 Hz 23 KHz Sensitivity 29 dB 1 KHz Audio output 230 mV Connections 2 x RJ45 1 x RCA Aux IN Dimensions base 160 x 190 x 55 mm LxWxH Dimensions microphone 20 x 445 mm WxH Weight 1 kg Optional acces...

Page 7: ...ired zone Press the ALL button to activate all 6 zones at maximum volume level If you use a single PM Six and Chime mode is active press the TALK button wait until the chime sound passes and then talk When Chime mode is inactive always press this button to talk If you use multiple devices and DIP switch 2 is set to PRIORITY position press the TALK button to talk If DIP switch 2 is set to SLAVE pos...

Page 8: ... the master device to the LINK connector on the slave device etc Microphone RJ45 OUT Use this connector to connect the PM Six to another PM s LINK connector or to the input connector on the ZPA 6240TU RCA Aux IN External audio input Transmits the MIC signal and the mixed voice to the host Microphone sensitivity control Turn the control to set the microphone s sensitivity Installation Remove all pa...

Page 9: ...tted to the selected zone s Message Bank 01 Press one of the message buttons 02 to select the desired message 02 Press one of the zone buttons 1 6 05 or the ALL button to select the desired zone s at maximum volume level If you use multiple amplifiers the ALL button will not function 03 Press the Repeat Stop button continuous playback or Start Stop button single playback to activate deactivate pla...

Page 10: ...it to the RJ45 connector as shown in the picture below fig 05 The wires should now be colored as follows Fig 05 Maintenance The DAP Audio PM Six requires almost no maintenance However you should keep the unit clean Disconnect the mains power supply and then wipe the cover with a damp cloth Do not immerse in liquid Do not use alcohol or solvents Keep connections clean Disconnect electric power and ...

Page 11: ... Signal link RJ45 IN Signal output RJ45 OUT Auxiliary input RCA IN Electro mechanical effects Microphone unit condenser Frequency response 22 Hz 23 KHz Sensitivity 29 dB 1 KHz Audio output 230 mV Max ambient temperature ta 40 C Max housing temperature tB 80 C Design and product specifications are subject to change without prior notice Website www Dap audio info Email service highlite nl ...

Page 12: ... 2016 DAP Audio ...

Reviews: