background image

 

  

 

 

   

 

IMIX 7.3 

Ordercode: D2351  

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the system. 
 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this system to a dimmerpack. 

 

Do not switch the system on and off in short intervals, as this would reduce the system’s life. 

 

Do not open the device and do not modify the device. 

 

Do not drive the inputs with a signal level bigger, than required to drive the equipment to full output. 

 

Do not plug Mics into the console (or stagebox) while Phantom Power is on. Also mute the monitor / 
Pa system when turning Phantom Power on or off. Allow the system to adjust for a couple of seconds, 
before setting the input gains. 

 

Only use system indoor, avoid contact with water or other liquids. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always disconnect power from the mains, when system is not used. Only handle the power-cord by 
the plug. Never pull out the plug by tugging the power-cord. 

 

Always operate the unit with the AC ground wire connected to the electrical system ground. 

 

Make sure you don’t use the wrong kind of cables or defective cables. 

 

Make sure that the signals into the mixer are balanced, otherwise hum could be created. 

 

Make sure you use DI boxes to balance unbalanced signals; All incoming signals should be clear. 

 

Make sure that the available voltage is not higher than stated on the rear panel.  

 

Make sure that the power-cord is never crimped or damaged. Check the system and the power-
cord from time to time. 

 

Please turn off the power switch, when changing the power cord or signal cable, or select the input 
mode switch. 

 

Extreme frequency boosts in connection with a high input signal level may lead to overdriving your 
equipment. Should this occur, it is necessary to reduce the input signal level by using the INPUT 
control. 

 

To emphasize a frequency range, you don’t necessarily have to move its respective control upward; 
try lowering surrounding frequency ranges instead. This way, you avoid causing the next piece of 
equipment in your sound path to overdrive. You also preserve valuable dynamic reserve 
(“headroom”) 

 

Avoid ground loops! Always be sure to connect the power amps and the mixing console to the 
same electrical circuit to ensure the same phase! 

 

If system is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your system. Leave the 
system switched off until it has reached room temperature. 

 

If your Dap Audio device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Dap Audio dealer for service. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

For replacement use fuses of same type and rating only. 

 

WARRANTY: Till one year after date of purchase. 

 

 

Summary of Contents for IMIX-7.3

Page 1: ...IMIX 7 3 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D2351 MANUAL ENGLISH...

Page 2: ...2 Operating Determinations 4 Connection with the mains 4 Return Procedure 4 Claims 4 Description of the device 5 Features 5 Overview 5 Front 5 Rear 6 Installation 6 Functions 7 Set Up and Operation 1...

Page 3: ...lation operation and maintenance of this system has to be qualified follow the instructions of this manual Before you initial start up please make sure that there is no damage caused by transportation...

Page 4: ...e DI boxes to balance unbalanced signals All incoming signals should be clear Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never cr...

Page 5: ...sure to properly pack fixture any shipping damage resulting from inadequate packaging is the customer s responsibility Highlite reserves the right to use its own discretion to repair or replace produ...

Page 6: ...PFL button channel 1 5 Zone select button all channels Channel fader channel 1 5 Peak LED mic 1 2 Master control master 1 3 Low control mic 1 2 VU meter master 1 3 Mid control mic1 2 Zone select butto...

Page 7: ...nbalanced out connector Channel 3 gain control Channel 5 line 1 line 2 input connectors Channel 2 gain control Channel 4 line 1 line 2 input connectors Channel 1 gain control Channel 3 line 1 line 2 i...

Page 8: ...channel s equalizer section allows shaping of the incoming audio signal All mono input channels are fitted with 3 band EQ The high 6 and low 4 shelving controls have their frequencies fixed at 12KHz a...

Page 9: ...e fader setting It is possible to assign more than one channel simultaneous to the PFL bus 18 Channel fader A logarithmic 50mm fader which controls the volume of the corresponding channel The overall...

Page 10: ...ht amplifies the frequency range turning to the left attenuates the signal Minor changes to the Equalizer control usually produce the best results Try to avoid excessive enhancement of the mid band 28...

Page 11: ...put levels 39 Channel 4 gain control Channel 4 input level is determined by the gain control With the gain control you can adjust the line input sensitivity while optimally matching the incoming signa...

Page 12: ...e these outputs to connect an amplifier with unbalanced inputs 52 Master 1 XLR balanced out connectors Use these outputs to connect an amplifier with balanced inputs 53 Master 1 RCA unbalanced out con...

Page 13: ...discharges etc are caused entirely by using unsuitable or faulty cables Unbalanced Balanced For these applications the unit provides 1 4 TRS and XLR connectors to easily interface with most profession...

Page 14: ...again 4 If nothing happens after 30 seconds unplug the device 5 Return the device to your DAP Audio dealer Product Specification Input channels 2 x Microphone combo XLR Jack 11 x Line RCA 2 x Phono R...

Page 15: ...14 IMIX 7 3 Ordercode D2351 Block diagram...

Page 16: ...2013 DAP Audio...

Reviews: