background image

 

      Return Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

1) Your name 
2) Your address 
3) Your phone number 
4) A brief description of the symptoms 
 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
 It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 
 

Summary of Contents for DCX-36 MKII

Page 1: ...DCX 36 MKII ORDERCODE D2023...

Page 2: ...AP Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our...

Page 3: ...Operating Determinations Return Procedure Claims Description Features Overview Front side Overview Back side Installation Set Up and Operation X over submenu Safety Options System Menu Interface Menu...

Page 4: ...perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Please consider that damages caused...

Page 5: ...e to connect the power amps and the mixing console to the same electrical circuit to ensure the same phase If system is dropped or struck disconnect mains power supply immediately Have a qualified eng...

Page 6: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 7: ...protecting the program settings Phase Invert switch per output USB interface for remote control including PC software 2x XLR Input and 6x XLR Output Clip LED Software included for easy set up with DCX...

Page 8: ...cted properly Main Menu Press the Menu 14 button to enter the main menu Select the desired submenu by pressing the Back 2 or Next 3 buttons and confirm your setting with the Enter 4 button Xover subme...

Page 9: ...to the preset output volume Mute Hold all output remains muted 4 Delay Time Distance You can adjust the delay in milli seconds ms meters m feet ft Interface menu Interface Setup Baud Rate Here you can...

Page 10: ...f the equalizer is activated you can adjust the frequency 20 Hz to 20 kHz the Q factor 0 5 to 10 and the gain 12 dB 1 dB By pressing the Parameter 17 knob you can jump to the next parameter Additional...

Page 11: ...er_1025 EXE Next you have to install the DCX software by clicking on DCXSetup_V13 EXE Now connect the DCX 36 MKII via a USB cable to your computer Start up the DCX software by double Clicking the DCX...

Page 12: ...e the Device ID matches the ID in your DCX 36 MKII factory set to 1 Now press OK and select RS232 in the Config menu Your screen will look as the figure below The DCX USB driver emulates a RS 232 port...

Page 13: ...eal time editing you ll have to store the new settings to the DCX 36MKII first If you want to edit a program stored in the DCX 36 MKII you ll have to press the Refresh button in the Memory window firs...

Page 14: ...12 Delay Settings Limiter Settings...

Page 15: ...13 Out 1 Settings Filter Settings...

Page 16: ...14 Out 2 Settings Out 3 Settings...

Page 17: ...15 Out 4 Settings Out 5 Settings...

Page 18: ...r settings select a memory location press store and your settings will be stored Click the erase button to erase a program you re not happy with Or click erase all to erase all programs in the DCX mem...

Page 19: ...17...

Page 20: ...18...

Page 21: ...s and twists when coiling them This gives the advantage of increasing their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are...

Page 22: ...2 Insert a flat head screwdriver into a slot in the fuse cover Gently pry up the fuse cover 3 Remove the used fuse If brown or unclear it is burned out 4 Insert the replacement fuse into the holder w...

Page 23: ...aration 80 dB 30 Hz 20 KHz Crossover frequency 15 Hz 20 kHz Maximum output level Vpp 7 6V THD 0 005 Latency 180 s Delay Delay time 0 7 ms Parametric Equalizer Filter Gain 12 dB in 1 dB steps Central F...

Page 24: ...22 Design and product specifications are subject to change without prior notice Website www Dap audio info Email service highlite nl...

Page 25: ...2009 DapAudio...

Reviews:

Related manuals for DCX-36 MKII