Page 10
Control Module Jumper Configuration
A 3-pin header (JH1) configures the relay switch closure. This header is located near the
front panel just behind the BNC connector.
If a system failure occurs, the switch closure is open when the shorting jumper is in
the NC position.
If a system failure occurs, the switch closure is closed when the shorting jumper is in
the NO position.
The factory default position is NC (closed during normal operation and open during
a failure).
Control Module Cables
The Control Module may be connected to a computer using either a RS-232 connec-
tion or a USB connection.
A standard DB9F to DB9M cable with no twists is used for the RS-232 connection.
A standard USB cable with a B connector on the Control Module side is used for a USB
connection. Consult the factory for USB device drivers.
Terminal Configuration
Port Settings should be set as listed:
Bits per second:
38400
Data bits:
8
Parity:
None
Stop bits:
1
Flow control:
None