Unit description 

The unit is designed for automated, versatile and trouble-free  air dehumidification.
The unit operates on condensation principle. It is equipped with a closed loop cooling system, 
low noise and low maintenance fan and with a power cable with a plug.
The unit's control panel is equipped with a LCD display used for the system functional checks. 
A fully automated unit control system, a trouble-free regulated humidistat, an integrated 
overflow system as well as flexible hose connection for direct  condensation discharge assure 
fail safe and long-term operation of the unit.  

The unit complies with the fundamental safety and health requirements of the existing EU 
regulations.

The unit is easy and safe to operate.
 

Unit location 

The unit is operated in the buildings where dry air is necessary to prevent  significant financial 
losses (for example, due to mould formation). 

The unit is mainly used for drying and dehumidification of: 
◊ Industrial buildings of various applications, storage rooms and cellar rooms. 
It is also used for dry air maintenance in: 
◊ Storage areas, archives, laboratories. 
◊ Laundries, changing rooms etc. 

Functions

The unit operates on condensation principle. 

The fan

 intakes moist surrounding air into the units rear side through the air filter, evaporator 

and condenser located behind the evaporator. 
Heat is extracted at the cold evaporator. The air is cooled to below the dew point. The water 
vapor contained in the room air deposits as condensate or frost on the evaporator fins.

Summary of Contents for DEH-1600i

Page 1: ...DanVex DEH 1600i DanVex DEH 1900i Dehumidifiers Operation manual...

Page 2: ...R www danvex fi 1...

Page 3: ...fication principles Attention These units cannot be used for air cooling Use of DanVex dehumidifier Despite of windows and doors insulation quality damp and moisture can penetrate even through thick c...

Page 4: ...utside 2 By the air dehumidification The moist air in an enclosed room is continuously dehumidified by the condensation principle or by other dehumidification method In terms of energy consumption the...

Page 5: ...led the maximum water vapor volume that can be absorbed continuously reduces the water vapor volume contained in the air remains however the same and the relative humidity increases If the air tempera...

Page 6: ...dehumidifier The air flow is cooled on the way through the evaporator condenser system till its temperature is below the dew point Water vapor condenses it is collected in a condensate trap inside the...

Page 7: ...s or in case the unit is not used for the intended purpose The following safety instructions must be observed It is prohibited to install or operate the units in the locations subject to explosion haz...

Page 8: ...h requirements of the existing EU regulations The unit is easy and safe to operate Unit location The unit is operated in the buildings where dry air is necessary to prevent significant financial losse...

Page 9: ...nd from outside Windows and doors must be closed to prevent free air exchange between the room and ambient atmosphere If the unit is used in dust laden environments it is necessary to take appropriate...

Page 10: ...R www danvex fi 9 Explode drawing...

Page 11: ...standby mode press timer to set Auto starting time on time will flash in screen and click or to adjust the time B In working mode press timer to set Auto stop time off time will flash in screen and cl...

Page 12: ...it is in operation it will operate the mode of preset stop time We do not ensure the efficient operation of the unit if the room temperature is below 10 C and if the relative humidity is below 40 Oper...

Page 13: ...ore the current status before the power is cut and enter the operation mode before power cut automatically after power is supplied 5 Range for humidity is 20 90 6 If the dehumidifier is going to be sp...

Page 14: ...at temperature around pipe may result in icing continuous water drain is not allowed Do not repair disassemble or alternate the machine without authorization so as to avoid fire or electric shock acci...

Page 15: ...ed solidly 2 The filter mesh is blocked 1 Place the machine firmly 2 Clear the filter mesh Common Troubleshooting 1 Where the above troubles cannot be fixed and repair is needed please contact supplie...

Page 16: ...R www danvex fi Attachment Electrical diagram 15...

Page 17: ...DanVex request has a right to inspect the defective parts and to check the correctness of the warranty claim Warranty repair execution conditions The damage occurred during the equipment normal operat...