Unit description
The unit is designed for automated, versatile and trouble-free air dehumidification.
The unit operates on condensation principle. It is equipped with a closed loop cooling system,
low noise and low maintenance fan and with a power cable with a plug.
The unit's control panel is equipped with a LCD display used for the system functional checks.
A fully automated unit control system, a trouble-free regulated humidistat, an integrated
overflow system as well as flexible hose connection for direct condensation discharge assure
fail safe and long-term operation of the unit.
The unit complies with the fundamental safety and health requirements of the existing EU
regulations.
The unit is easy and safe to operate.
Unit location
The unit is operated in the buildings where dry air is necessary to prevent significant financial
losses (for example, due to mould formation).
The unit is mainly used for drying and dehumidification of:
◊ Industrial buildings of various applications, storage rooms and cellar rooms.
It is also used for dry air maintenance in:
◊ Storage areas, archives, laboratories.
◊ Laundries, changing rooms etc.
Functions
The unit operates on condensation principle.
The fan
intakes moist surrounding air into the units rear side through the air filter, evaporator
and condenser located behind the evaporator.
Heat is extracted at the cold evaporator. The air is cooled to below the dew point. The water
vapor contained in the room air deposits as condensate or frost on the evaporator fins.