1. If the set humidity is higher than the actual humidity, the dehumidifier stops working;

2.

During dehumidification, after the compressor starts working, the fan and compressor

can only be stopped after working for at least 3 minutes; the compressor can only be

re-started 3 minutes after stops;

3.

If works  under low  temperature, the  dehumidifier  may judge  the  system

temperature automatically and defrosts automatically; when defrosting, the indicator of

defrosting is light, the fan works and compressor stops working.

4. The system has auto memory. When all the mode setting has been finished, if there is

sudden power cut during operation, or the power jack slips out, the system may store

the current status before the power is cut and enter the operation mode before power

cut automatically after power is supplied;

5. Range for humidity is 20% -90%;

6. If the dehumidifier is going to be spared for a long time, please unload the  power cord

or cut the power.

7. Auto detection of temperature /humidity failure.

a. When the system detects that temperature sensor exceeds the limited range, the system

enters mode of temperature sensor failure. Under this mode, LCD displays temperature

failure code“E1”,the system works in circle of dehumidification for 30 minutes and

defrosting for 15 minutes;

b. When the system detects that humidity sensor exceeds the limited range, the system

enters mode of humidity sensor failure. Under this mode, LCD displays humidity failure

code“E2”and the system enters continuous dehumidification.

c. After  temperature  /humidity  sensor  failure  is  limited,  the  system  works normally.

Summary of Contents for DEH-1600i

Page 1: ...DanVex DEH 1600i DanVex DEH 1900i Dehumidifiers Operation manual...

Page 2: ...R www danvex fi 1...

Page 3: ...fication principles Attention These units cannot be used for air cooling Use of DanVex dehumidifier Despite of windows and doors insulation quality damp and moisture can penetrate even through thick c...

Page 4: ...utside 2 By the air dehumidification The moist air in an enclosed room is continuously dehumidified by the condensation principle or by other dehumidification method In terms of energy consumption the...

Page 5: ...led the maximum water vapor volume that can be absorbed continuously reduces the water vapor volume contained in the air remains however the same and the relative humidity increases If the air tempera...

Page 6: ...dehumidifier The air flow is cooled on the way through the evaporator condenser system till its temperature is below the dew point Water vapor condenses it is collected in a condensate trap inside the...

Page 7: ...s or in case the unit is not used for the intended purpose The following safety instructions must be observed It is prohibited to install or operate the units in the locations subject to explosion haz...

Page 8: ...h requirements of the existing EU regulations The unit is easy and safe to operate Unit location The unit is operated in the buildings where dry air is necessary to prevent significant financial losse...

Page 9: ...nd from outside Windows and doors must be closed to prevent free air exchange between the room and ambient atmosphere If the unit is used in dust laden environments it is necessary to take appropriate...

Page 10: ...R www danvex fi 9 Explode drawing...

Page 11: ...standby mode press timer to set Auto starting time on time will flash in screen and click or to adjust the time B In working mode press timer to set Auto stop time off time will flash in screen and cl...

Page 12: ...it is in operation it will operate the mode of preset stop time We do not ensure the efficient operation of the unit if the room temperature is below 10 C and if the relative humidity is below 40 Oper...

Page 13: ...ore the current status before the power is cut and enter the operation mode before power cut automatically after power is supplied 5 Range for humidity is 20 90 6 If the dehumidifier is going to be sp...

Page 14: ...at temperature around pipe may result in icing continuous water drain is not allowed Do not repair disassemble or alternate the machine without authorization so as to avoid fire or electric shock acci...

Page 15: ...ed solidly 2 The filter mesh is blocked 1 Place the machine firmly 2 Clear the filter mesh Common Troubleshooting 1 Where the above troubles cannot be fixed and repair is needed please contact supplie...

Page 16: ...R www danvex fi Attachment Electrical diagram 15...

Page 17: ...DanVex request has a right to inspect the defective parts and to check the correctness of the warranty claim Warranty repair execution conditions The damage occurred during the equipment normal operat...

Page 18: ......