16
www.danvex.fi
B. Factory parameters
Long press
for 5 seconds to enter the factory parameters setting mode: the parameters
code R,P,O,H,C,A,D,F will appear.
Press
or
to select the parameters code R,P,O,H,C,A,D,F;
Short press
to set the available code;
Press
or
to adjust the code value;
Short press
to save the code value ;
Short press
to exit without saving during the code value setting or return to the previous
page.
Long press
&
&
simultaneously for 3 seconds to reboot the controller’s setting.
10 seconds without setting, the value will not be saved and exit to the home screen.
4.1.4 Icon's meaning
Icon
Description
WIFI connection established
WIFI connection not established
ESP32 trigger
Defrost
Filter max. working time alarm,disappear after reset
Compressor relay output active
*Compressor working
*Flashing when the minimum absolute humidity protection is activated
Humidification
Timer
H05=1,temperature in degrees Fahrenheit
H05=0,temperature in degrees Celsius
Current humidity
Current air speed, AC 3 speeds, EC 1~5 speed
100% return air
100% fresh air
Mixed fresh and return air
Dehumidification mode
Cooling mode
Heating mode