background image

R

www.danvex.fi

Safety instructions 

All persons admitted to operate or maintain the 

DanVex AD-550 

dehumidifiers should read these 

instructions manual and to

 

be briefed for its safe operation

.

Only the personnel with sufficient knowledge of the dehumidifiers operation principle is permitted 
to perform the adsorption dehumidifiers operation and maintenance.     

Only authorized personnel 

with special education 

is permitted to perform 

maintenance and repair 

works

 on electrical system.

Only authorized service center personnel is permitted to perform repair works on electrical 
components.

It is prohibited to install or operate the units in the locations subject to explosion hazard.

Before opening any panels of the unit body it is required to disconnect the dehumidifier from 
the mains

.

Before  starting  any  maintenance  works  the  dehumidifier  should  be  out-of-operation  for  15 
minutes. 

The unit's panels must be always closed except when the dehumidifier is being maintained

.

The dehumidifier can be used for air drying at atmospheric pressure only

.

Never use the dehumidifier without filters since the drying rotor can get contaminated which will 
cause loss of efficiency

.

This manual should always be at hand and not far from the dehumidifier

.

The dehumidifier maintenance and inspection works should be performed in accordance with a 
fixed schedule

.

Only original spare parts should be used.

It is required to receive a written approval from 

«DanVex Оу

.

» 

or from its local representative 

for any changes or modifications of the dehumidifier.  

3

Summary of Contents for AD-550

Page 1: ...DanVex AD 550 Adsorption air dehumidifier Operation manual...

Page 2: ...R www danvex fi...

Page 3: ...instructions 3 Introduction 4 Purpose 4 Design 4 Control board introduction 5 Operation principle 6 Dimensions and weight 6 Installation 7 Technical data 8 Commissioning 8 Maintenance 9 Transportatio...

Page 4: ...osion hazard Before opening any panels of the unit body it is required to disconnect the dehumidifier from the mains Before starting any maintenance works the dehumidifier should be out of operation f...

Page 5: ...licaGel and assures a very large contact area with air flow for moisture adsorption in the small volume of the rotor This material is highly efficient for water molecules attraction and retention it i...

Page 6: ...re are three numbers totally in the screen shows the ambient RH level it testing lower LED screen there are three numbers in the screen shows the setted RH level c State of setting up Click O button t...

Page 7: ...umidification process is assured The air flow used for the rotor matrix regeneration is called regeneration air REGENERATION AIR It is heated up to 120 and when passing through a small sector it remov...

Page 8: ...stall the moist air duct upright it should be insulated and drain holes should be drilled in the lowest part of the elbow bend 2 4 mm Regeneration air duct The regeneration air duct should be as short...

Page 9: ...required RH value when doing so 5d should be displayed in the upper line the bottom line should display the value being set Then set the humidity change value relative to the set value at which the de...

Page 10: ...once per month Never use the dehumidifier without filters Rotor The rotor is maintenance free However for cleaning purposes it can be flushed out by compressed air A rotor cleaning procedure requires...

Page 11: ...tions when it supplies the Customer a repaired or a spare part Parts repair or replacement does not result in the warranty period extension The parts and components replaced under the warranty belong...

Page 12: ......

Reviews: