![Dantherm HCH 5 Installation And Service Manual Download Page 11](http://html1.mh-extra.com/html/dantherm/hch-5/hch-5_installation-and-service-manual_3497101011.webp)
9
060804
•
Ve
rs
ion
1.6
•
22.01.2
01
9
en
Fittings and installations,
continued
Mounting the unit,
continued
Step
Action
5
Mount the drainage hose
*)
on the connection piece. The hose can be difficult
to connect to the connection piece. When the hose is about to be mounted it
can be helpful to warm up the hose prior to mounting, thereby it will be more
flexible to work with. Use lubricant on the hose if necessary, so that it can
smooth over the connection piece and maybe a hose clamp (not delivered)
*)
Drainage hose is not supplied. Use a 3/4" reinforced hose, which cannot be
broken or crushed flat. Dantherm recommends a transparent type with iron
wire, so it is possible to inspect the water trap
6
Lead the drainage hose through the ceiling construction and insulate up above
the hose connection piece:
Make sure that the drainage and drain pipe are always frost proof. A frozen
drain pipe can lead to damage. If it cannot be assured to keep the drainage
and drain pipe frost proof, Dantherm recommends connecting a heating cable
around the drain pipe. See more about this in the accessories list in the sec-
tion “Accessories” in the user’s guide.
Continued overleaf
Summary of Contents for HCH 5
Page 1: ...HCH 5 HCH 8 Installation and Service manual Rev 1 6 en da de fr ...
Page 42: ...8 Fortsættes på næste side 1000 mm 1500 mm 100 mm Min 50 mm komprimeret isolering ...
Page 74: ...8 Fortsetzung nächste Seite 100 mm 1000 mm 1500 mm Min 50 mm komprimierte Isolierung ...
Page 101: ...35 060804 Version 1 6 22 01 2019 DA de ...
Page 102: ...36 ...
Page 139: ...1 074913 Version 1 0 02 10 2012 ...
Page 140: ...2 060804 060804 ...